Background: Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT). In this project, the non-imaging probe of the fhSPECT system was replaced by a unique handheld gamma camera containing an array of sodium iodide crystals optically coupled to an array of silicon photomultipliers (SiPMs). A feasibility study was performed in which preoperative SLN mapping was performed using camera fhSPECT and the number of detected nodes was compared to that visualized by lymphoscintigraphy, probe fhSPECT, and to the number ultimately excised under non-imaging probe guidance.

Results: Among five subjects, SLNs were detected in nine lymphatic basins, with one to five SLNs detected per basin. A basin-by-basin comparison showed that the number of SLNs detected using camera fhSPECT exceeded that using lymphoscintigraphy and probe fhSPECT in seven of nine basins and five of five basins, respectively. (Probe fhSPECT scans were not performed for four basins.) It exceeded the number excised under non-imaging probe guidance for seven of nine basins and equaled the number excised for the other two basins.

Conclusions: Freehand SPECT using a prototype SiPM-based gamma camera demonstrates high sensitivity for detection of SLNs in a preoperative setting. Camera fhSPECT is a potential means for efficiently obtaining real-time 3D activity distribution maps in applications such as image-guided percutaneous biopsy, and surgical SLN biopsy or radioguided tumor excision.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7658290PMC
http://dx.doi.org/10.1186/s13550-020-00729-8DOI Listing

Publication Analysis

Top Keywords

probe fhspect
16
freehand spect
12
non-imaging probe
12
camera fhspect
12
slns detected
12
sentinel lymph
8
lymph node
8
node mapping
8
sln biopsy
8
probe
8

Similar Publications

Parathyroidectomy for primary hyperparathyroidism (PHPT) could have poor outcomes, even with accurate preoperative localization of the adenomas, because their intraoperative localization can be challenging. Freehand single photon emission computed tomography (fhSPECT) is a new technique for radio-guided intraoperative navigation. Its use during parathyroidectomy could be useful and such data are limited.

View Article and Find Full Text PDF

The aim of this prospective pilot study was to evaluate the feasibility of a new hybrid imaging modality, free-hand single-photon computed tomography/ultrasonography (fhSPECT/US), for preoperative localization of parathyroid adenomas and to compare its performance with conventional ultrasonography and SPECT/CT. Twelve patients diagnosed with primary hyperparathyroidism underwent sequentially US and parathyroid scintigraphy, including SPECT/CT, followed by fhSPECT/US, allowing for real-time fusion between US and freehand-generated gamma-camera images. The fhSPECT/US detection rates were correlated with histopathology, when available, or with the imaging modality showing the most lesions.

View Article and Find Full Text PDF

Introduction: The diagnostic and therapeutic approach to axillary lymph nodes is considered indispensable in the treatment of breast cancer patients.

Aim: To investigate the effectiveness of 3D freehand SPECT (fhSPECT) in sentinel lymph node (SLN) mapping in breast cancer, compared with the use of a conventional gamma probe.

Material And Methods: We retrospectively compared the fhSPECT lymph node mapping modality, with gamma probe detection in early-stage, clinically node-negative breast cancer patients, with biopsy-confirmed malignancy.

View Article and Find Full Text PDF

Background: Assessment of lymphatic status via sentinel lymph node (SLN) biopsy is an integral and crucial part of melanoma surgical oncology. The most common technique for sentinel node mapping is preoperative planar scintigraphy of an injected gamma-emitting lymphatic tracer followed by intraoperative node localization using a non-imaging gamma probe with auditory feedback. In recent years, intraoperative visualization of SLNs in 3D has become possible by coupling the probe to an external system capable of tracking its location and orientation as it is read out, thereby enabling computation of the 3D distribution of the tracer (freehand SPECT).

View Article and Find Full Text PDF

Within image-guided surgery, 'hybrid' guidance technologies have been used to integrate the complementary features of radioactive guidance and fluorescence guidance. Here, we explore how the generation of a novel freehand fluorescence (fhFluo) imaging approach complements freehand SPECT (fhSPECT) in a hybrid setup. Near-infrared optical tracking was used to register the position and the orientation of a hybrid opto-nuclear detection probe while recording its readings.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!