A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of an Eight-Channel Time-Based Readout ASIC for PET Applications. | LitMetric

An eight-channel readout ASIC has been developed for reading output signals from solid-state photomultipliers for positron emission tomography applications. This ASIC converts both the signal charge and occurring time to digital timing pulses so that only a time-to-digital converter is required for further signal processing. This provides the advantages of simplified circuit design, reduced power consumption, and suitability for applications that have a large number of readout channels. The ASIC uses a fully current mode preamplifier to achieve high bandwidth (> 100 MHz), high time resolution (better than ~1 ns FWHM), and low power consumption (a few mW/ch). The linear dynamic range of charge measurement is adjustable and can be extended up to 10 pC. The chip has been fabricated with 0.35 m 2P4M CMOS technology. A test prototype board has been developed and used for ASIC functionality and performance evaluation. Our preliminary studies show that the targets have been successfully achieved.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7648716PMC
http://dx.doi.org/10.1109/TNS.2011.2165557DOI Listing

Publication Analysis

Top Keywords

readout asic
8
power consumption
8
asic
5
development eight-channel
4
eight-channel time-based
4
time-based readout
4
asic pet
4
pet applications
4
applications eight-channel
4
eight-channel readout
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!