Simultaneous quantification of dabrafenib, hydroxy-dabrafenib and trametinib in human plasma by liquid chromatography-tandem mass spectrometry.

J Pharm Biomed Anal

Department of Pharmacokinetics and Pharmacochemistry, Cochin Hospital, AP-HP, CARPEM, 75014 Paris, France; UMR8038 CNRS, U1268 INSERM, Faculty of Pharmacy, University of Paris, PRES Sorbonne Paris Cité, CARPEM, 75006 Paris, France.

Published: January 2021

A new liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of dabrafenib (DAB), its main metabolite hydroxy-dabrafenib (OHD) and trametinib (TRA) in human plasma has been developed and validated. After addition of internal standard (dabrafenib-d9), extraction was achieved after protein precipitation with acetonitrile containing 1 % (v/v) formic acid. Chromatographic separation was performed on an Accucore® C18 (2.1 × 50 mm; 2.6 μm) column using a gradient elution of water acidified with 0.1 % (v/v) formic acid (A) and acetonitrile containing 0.1 % (v/v) formic acid (B) at a flow rate of 500 μL/min. The calibration ranged from 10 to 2000 ng/mL for DAB and OHD and from 5 to 50 ng/mL for TRA. This method was validated with satisfactory results including good precision (intra- and inter-assay coefficient of variation from 2.0 %-14.9 %) and good accuracy (inter- and intra-day bias between -1.2 % and 10.9 %), as well as long term stability in unprocessed plasma at -20 °C. This newly proposed method is useful for clinical research purposes as well as therapeutic drug monitoring for patients with a Rapidly Accelerated Fibrosarcoma kinase B (BRAF)-mutated cancer.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jpba.2020.113718DOI Listing

Publication Analysis

Top Keywords

v/v formic
12
formic acid
12
simultaneous quantification
8
quantification dabrafenib
8
human plasma
8
liquid chromatography-tandem
8
chromatography-tandem mass
8
mass spectrometry
8
acetonitrile v/v
8
dabrafenib hydroxy-dabrafenib
4

Similar Publications

Background: Tavaborole (TAV), a benzoxaborole derivative, is an FDA-approved antifungal agent for treating onychomycosis, a common and persistent fungal infection of the toenails.

Objective: This study aimed to develop a robust stability-indicating HPTLC method to determine TAV in nanostructured lipid carriers (NLC) using a comprehensive approach that includes risk assessment, and Analytical Quality by Design.

Methods: The critical method parameters influencing the HPTLC results were screened using a Placket-Burman screening design followed by its optimization using a central composite optimization design.

View Article and Find Full Text PDF

In this study, we reported a novel reverse-phase UPLC method for the simultaneous estimation of nitrite and nitrate ions using a Quality by Design (QbD) approach. Nitrite and nitrate ions were separated on an ACQUITY CSH Fluoro-Phenyl column (100 × 2.1 mm, 1.

View Article and Find Full Text PDF

An analytical method for identifying the chemical constituents in the Chinese herbal combination Jiuwei decoction was established using capillary electrophoresis coupled with quadrupole time-of-flight mass spectrometry. Nine herbs were extracted with a 60:40 (v/v) ethanol/water solution to prepare the Jiuwei decoction. Electrophoretic separation was carried out using a 50 µm i.

View Article and Find Full Text PDF

The medicinal fungus Phellinus Igniarius (P. igniarius) has been demonstrated to possess a variety of pharmacological effects, including anti-oxidant, anti-tumor, blood circulation promotion, anti-diarrheal and sedative properties, etc. In order to gain a deeper understanding of the components in P.

View Article and Find Full Text PDF

Lysinoalanine (LAL), commonly formed in high-protein foods, raises concerns due to its nephrotoxicity and potential reduction in nutritional properties, making its accurate detection crucial for food safety. Liquid chromatography-tandem quadrupole mass spectrometry (LC-QQQ) plays a pivotal role in the quantification of compounds, and its accuracy and sensitivity are significantly influenced by specific liquid chromatography (LC) and mass spectrometry (MS) parameters. However, the procedure and considerations for LC and MS parameters optimization have often not been discussed in depth in existing literature.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!