Background: All randomised phase 3 studies of selective internal radiation therapy for advanced hepatocellular carcinoma published to date have reported negative results. However, these studies did not use personalised dosimetry. We aimed to compare the efficacy of a personalised versus standard dosimetry approach of selective internal radiation therapy with yttrium-90-loaded glass microspheres in patients with hepatocellular carcinoma.
Methods: DOSISPHERE-01 was a randomised, multicentre, open-label phase 2 trial done at four health-care centres in France. Patients were eligible if they were aged 18 years or older and had unresectable locally advanced hepatocellular carcinoma, at least one measurable lesion 7 cm or more in size, a hepatic reserve of at least 30% after selective internal radiation therapy, no extrahepatic spread (other than to the lymph nodes of the hilum, with a lesion <2 cm in size), and no contraindications to selective internal radiation therapy, as assessed by use of a technetium-99m macro-aggregated albumin scan. Patients were randomly assigned (1:1) by use of a permutated block method, with block sizes of four and without stratification, to receive either standard dosimetry (120 ± 20 Gy) targeted to the perfused lobe; standard dosimetry group) or personalised dosimetry (≥205 Gy targeted to the index lesion; personalised dosimetry group). Investigators, patients, and study staff were not masked to treatment. The primary endpoint was the investigator-assessed objective response rate in the index lesion, according to European Association for the Study of the Liver criteria, at 3 months after selective internal radiation therapy in the modified intention-to-treat population. Safety was assessed in all patients who received at least one selective internal radiation therapy injection, and analysed on the basis of the treatment actually received (defined by central dosimetry assessment). The trial is registered with ClinicalTrials.gov, NCT02582034, and has been completed.
Findings: Between Dec 5, 2015, and Jan 4, 2018, 93 patients were assessed for eligibility. Of these patients, 60 were randomly assigned: 31 to the personalised dosimetry group and 29 to the standard dosimetry group (intention-to-treat population). 56 (93%) patients (28 in each group) were treated (modified intention-to-treat population). In the modified intention-to-treat population, 20 (71% [95% CI 51-87]) of 28 patients in the personalised dosimetry group and ten (36% [19-56]) of 28 patients in the standard dosimetry group had an objective response (p=0·0074). In the safety analysis population, a least one serious adverse event was reported in seven (20%) of the 35 patients who received personalised dosimetry, and in seven (33%) of the 21 patients who received standard dosimetry. The most frequent (ie, occurring in >5% of patients) grade 3 or higher adverse events were ascites (one [3%] patient who received personalised dosimetry vs two [10%] patients who received standard dosimetry), hepatic failure (two [6%] vs none), lymphopenia (12 [34%] vs nine [43%]), increased aspartate aminotransferase concentrations (three [9%] vs two [10%]), increased alanine aminotransferase concentrations (three [9%] vs none), anaemia (two [6%] vs one [5%]), gastrointestinal haemorrhage (none vs two [10%]), and icterus (none vs two [10%]). One treatment-related death occurred in each group.
Interpretation: Compared with standard dosimetry, personalised dosimetry significantly improved the objective response rate in patients with locally advanced hepatocellular carcinoma. The results of this study suggest that personalised dosimetry is likely to improve outcomes in clinical practice and should be used in future trials of selective internal radiation therapy.
Funding: Biocompatibles UK, a Boston Scientific Group company.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/S2468-1253(20)30290-9 | DOI Listing |
Clin Infect Dis
January 2025
Charité - Universitätsmedizin Berlin, corporate member of Freie Universität Berlin and Humboldt-Universität zu Berlin, Department of Infectious Diseases, Respiratory Medicine and Critical Care, Berlin, Germany.
Background: Existing risk evaluation tools underperform in predicting intensive care unit (ICU) admission for patients with the Coronavirus Disease 2019 (COVID-19). This study aimed to develop and evaluate an accurate and calculator-free clinical tool for predicting ICU admission at emergency room (ER) presentation.
Methods: Data from patients with COVID-19 in a nationwide German cohort (March 2020-January 2023) were analyzed.
Introduction: Effective antimicrobial stewardship programs require data on antimicrobial consumption (AMC) and utilization (AMU) to guide interventions. However, such data is often scarce in low-resource settings. We describe the consumption and utilization of antibiotics at a large tertiary-level hospital in Uganda.
View Article and Find Full Text PDFJ Am Geriatr Soc
January 2025
Cancer Center Amsterdam, Cancer Treatment and Quality of Life, Amsterdam, The Netherlands.
Background: To ensure appropriate care for the individual older adult, an ideal treatment should align with patients' values. However, healthcare professionals struggle with how to elucidate patient values effectively. To offer guidance to healthcare professionals, we performed a scoping review, thereby mapping and categorizing instruments specifically developed to elucidate values of older adults in clinical practice.
View Article and Find Full Text PDFAnn Hematol
January 2025
Department of internal medicine, Albert Schweitzer Hospital, Dordrecht, The Netherlands.
Selected chronic myeloid leukemia (CML) patients may discontinue their tyrosine kinase inihibitor (TKI) in an attempt to achieve sustained treatment-free remission (TFR), which mitigates therapy-related side effects and limits treatment costs. TFR has been extensively studied following the discontinuation of adenosine triphosphate (ATP) - competitive TKI. However, there is minimal data concerning TFR after the discontinuation of the novel TKI asciminib.
View Article and Find Full Text PDFRheumatology (Oxford)
January 2025
The First Department of Internal Medicine, University of Occupational and Environmental Health, Japan.
The rheumatoid factor (RF) is a representative autoantibody against the crystallizable fragment (Fc) of denatured immunoglobulin (Ig) G that are primarily detected in patients with rheumatoid arthritis (RA). Although five types of tumor necrosis factor (TNF) inhibitors can be used to treat RA, no guidelines are available for selecting the appropriate inhibitor for treatment. High serum RF levels are associated with high disease activity, progressive joint destruction, life prognosis associated with organ damage, decreased treatment responsiveness to TNF inhibitors and other drugs, and low treatment retention rates.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!