Purpose: This paper aims at evaluating the effects of muscle load on knee kinematics and stability after TKA and second at evaluating the effect of TKA surgery on knee kinematics and stability; and third, at correlating the stability in passive conditions and the stability in active, muscle loaded conditions.
Methods: Fourteen fresh frozen cadaveric knee specimens were tested under passive and active condition with and without external loads involving a varus/valgus and internal/external rotational torque before and after TKA surgery using two in-house developed and previously validated test setups.
Results: Introduction of muscle force resulted in increased valgus (0.98°) and internal rotation of the femur (4.64°). TKA surgery also affected the neutral path kinematics, resulting in more varus (1.25°) and external rotation of the femur (5.22°). All laxities were significantly reduced by the introduction of the muscle load and after implantation of the TKA. The presence of the implant significantly affects the active varus/valgus laxity. This contrasts with the rotational laxity, in which case the passive laxity is the main determinant for the active laxity. For the varus/valgus laxity, the passive laxity is also a significant predictor of the active laxity.
Conclusion: Knee stability is clearly affected by the presence of muscle load. This points to the relevance of appropriate rehabilitation with focus on avoiding muscular atrophy. At the same time, the functional, muscle loaded stability strongly relates to the passive, ligament-based stability. It remains therefore important to assess knee stability at the time of surgery, since the passive laxity is the only predictor for functional stability in the operating theatre.
Level Of Evidence: Case series, Level IV.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00167-020-06329-2 | DOI Listing |
Med Biol Eng Comput
January 2025
Biomedical Engineering, Bahçeşehir University, Çırağan Caddesi Osmanpaşa Mektebi Sokak No: 4-6 Beşiktaş, İstanbul, 34353, Turkey.
This study aims to understand the impact of backpack carriage, a regular activity for many, on back muscles and joint mobility during walking so that clinicians can develop strategies or products to ensure individuals' safety and well-being. Surface electromyography (EMG) and XSENS Awinda motion capture systems were used to analyze the effects of carrying a backpack (12% of body weight) on erector spinae and multifidus muscles, as well as spinal, hip, knee, and ankle joints. Subjects walked at 4 km/h on flat and inclined surfaces.
View Article and Find Full Text PDFIntroduction: Load carriage is an inherent part of tactical operations. Critical speed (CS) has been associated with technical and combat-specific performance measures (e.g.
View Article and Find Full Text PDFBMC Sports Sci Med Rehabil
January 2025
Universite Lyon 1, Laboratoire Interuniversitaire de Biologie de la Motricité - UR 7424, UFRSTAPS, Villeurbanne, France.
Background: The Closed Kinetic Chain Upper Extremity Stability Test (CKCUEST) is a physical performance test designed to assess the upper extremity (UE) stability. However, only one outcome measure is provided for both UEs, limiting its application if the UEs are not similarly involved. Moreover, the changes in loads sustained by the support UE throughout the movement may influence the support UE stability.
View Article and Find Full Text PDFJ Control Release
January 2025
School of Pharmacy, Changzhou University, Changzhou 213164, China; School of Medical and Health Engineering, Changzhou University, Changzhou 213164, PR China. Electronic address:
Skin and soft tissue infections (SSTI) include bacterial infections of the skin, muscles, and connective tissue such as ligaments and tendons. SSTI in patients with immunocompromising diseases may lead to chronic, hard-to-heal infected wounds, resulting in disability, amputation, or even death. To treat SSTI and rebuild the defensive barrier of the skin, here we utilize recombinant type XVII collagen protein (rCol XVII) to construct biodegradable, regenerative collagen microneedles (rCol-MN) for transdermal delivery of antibacterial agents.
View Article and Find Full Text PDFCells
January 2025
Graduate School of Interdisciplinary Science and Engineering in Health Systems, Okayama University, Okayama 700-8530, Japan.
Boron (B) neutron capture therapy (BNCT) is a novel non-invasive targeted cancer therapy based on the nuclear capture reaction B (n, alpha) Li that enables the death of cancer cells without damaging neighboring normal cells. However, the development of clinically approved boron drugs remains challenging. We have previously reported on self-forming nanoparticles for drug delivery consisting of a biodegradable polymer, namely, "AB-type" Lactosome nanoparticles (AB-Lac particles)- highly loaded with hydrophobic B compounds, namely -Carborane (Carb) or 1,2-dihexyl--Carborane (diC6-Carb), and the latter (diC6-Carb) especially showed the "molecular glue" effect.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!