A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flat electron mirror. | LitMetric

Flat electron mirror.

Ultramicroscopy

Department of Imaging Physics, Delft University of Technology, Lorentzweg 1, 2628CJ Delft, The Netherlands.

Published: January 2021

Electron beams can be reflected by an electrode that is at a more negative potential than the cathode from which the beam is emitted. We want to design a mirror with a flat mirror electrode where the electrons are reflected at a plane very close to the electrode. The wave front of an electron can then be shaped when the mirror contains a surface topography or modulated potential. However, electron beams reflected by flat electron mirrors are usually characterized by high coefficients of chromatic and spherical aberration. When the mirror is combined with an electrostatic lens to form a tetrode mirror system, the situation deteriorates even further. This places a restrictive limit on the maximum aperture angle of the beam, and consequently also limits the attainable resolution at the image plane. We have numerically studied the dependence of these aberrations as a function of design parameters of the tetrode mirror consisting of a ground, lens, cap, and mirror electrode, and limited ourselves to only using flat electrodes with round apertures, at fixed electrode spacing. It turns out that the third order spherical aberration can be made negative. The negative third order aberration is then used to partially compensate the positive fifth order aberration. This way, a system configuration is obtained that, at 2 keV beam energy, provides a diffraction limited resolution of 7.6 nm at an image plane 25 mm from the mirror at beam semi-angles of 2.3 mrad, enabling an illumination radius of 40 μm at the mirror. The presented tetrode mirror design could spark innovative use of patterned electron mirrors as phase plates for electron microscopy in general, and for use as coherent beam splitters in Quantum Electron Microscopy in particular. An appendix presents a method to calculate the spot size of a focused beam in the presence of both third and fifth order spherical aberration coefficients, which is also applicable to Scanning (Transmission) Electron Microscopes with aberration correctors.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultramic.2020.113157DOI Listing

Publication Analysis

Top Keywords

spherical aberration
12
tetrode mirror
12
third order
12
mirror
11
flat electron
8
electron
8
electron beams
8
beams reflected
8
mirror electrode
8
electron mirrors
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!