Objective: Wideband absorbance and absorbed power were evaluated in a group of subjects with surgically confirmed otosclerosis (Oto group), mean age 51.6 years. This is the first use of absorbed power in the assessment of middle ear disorders. Results were compared with control data from two groups of adults, one with normal hearing (NH group) mean age of 31 years, and one that was age- and sex-matched with the Oto group and had sensorineural hearing loss (SNHL group). The goal was to assess group differences using absorbance and absorbed power, to determine test performance in detecting otosclerosis, and to evaluate preoperative and postoperative test results.
Design: Audiometric and wideband tests were performed over frequencies up to 8 kHz. The three groups were compared on wideband tests using analysis of variance to assess group mean differences. Receiver operating characteristic (ROC) curve analysis was also used to assess test accuracy at classifying ears as belonging to the Oto or control groups using the area under the ROC curve (AUC). A longitudinal design was used to compare preoperative and postoperative results at 3 and 6 months.
Results: There were significant mean differences in the wideband parameters between the Oto and control groups with generally lower absorbance and absorbed power for the Oto group at ambient and tympanometric peak pressure (TPP) depending on frequency. The SNHL group had more significant differences with the Oto group than did the NH group in the high frequencies for absorbed power at ambient pressure and tympanometric absorbed power at TPP, as well as for the tympanometric tails. The greatest accuracy for classifying ears as being in the Oto group or a control group was for absorbed power at ambient pressure at 0.71 kHz with an AUC of 0.81 comparing the Oto and NH groups. The greatest accuracy for an absorbance measure was for the comparison between the Oto and NH groups for the peak-to-negative tail condition with an AUC of 0.78. In contrast, the accuracy for classifying ears into the control or Oto groups for static acoustic admittance at 226 Hz was near chance performance, which is consistent with previous findings. There were significant mean differences between preoperative and postoperative tests for absorbance and absorbed power.
Conclusions: Consistent with previous studies, wideband absorbance showed better sensitivity for detecting the effects of otosclerosis on middle ear function than static acoustic admittance at 226 Hz. This study showed that wideband absorbed power is similarly sensitive and may perform even better in some instances than absorbance at classifying ears as having otosclerosis. The use of a group that was age- and sex-matched to the Oto group generally resulted in greater differences between groups in the high frequencies for absorbed power, suggesting that age-related norms in adults may be useful for the wideband clinical applications. Absorbance and absorbed power appear useful for monitoring changes in middle ear function following surgery for otosclerosis.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC8087617 | PMC |
http://dx.doi.org/10.1097/AUD.0000000000000968 | DOI Listing |
PLoS One
December 2024
College of Mechanical and Power Engineering, China Three Gorges University, Yichang, Hubei, The People's Republic of China.
The design parameters of the dynamic vibration absorber significantly affect the motion performance of the main vibration system. The Brock's approaching zero method was improved as approaching the fixed point frequency method. A general method of obtaining the explicit exact solution to the optimum damping ratio was presented to improve the accuracy of calculating the dynamic vibration absorber's optimum parameter.
View Article and Find Full Text PDFACS Appl Mater Interfaces
December 2024
School of Optoelectronic Science and Engineering, University of Electronic Science and Technology of China (UESTC), Chengdu 610054, PR China.
Low-dimensional hybrid organic-inorganic perovskites (HOIPs) containing chiral organic ligands have recently emerged as promising candidates for circularly polarized light (CPL) detection, which can distinguish left- and right-handed CPL directly. However, the increase in responsivity and realization of self-powered CPL photodetector remain a challenge. Meanwhile, there is a trade-off between the photocurrent responsivity and the ability to differentially absorb CPL in detectors based on these low-dimensional perovskites.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Mechanical and Aerospace Engineering, School of Engineering, University of Petroleum & Energy Studies (UPES), Dehradun, Uttarakhand, 248007, India.
This numerical investigation examines the performance and exergy analysis of parabolic trough solar collectors, focusing on the substitution of the conventional circular absorber with a rhombus-shaped absorber. By evaluating the thermal and fluid dynamics properties, this study aims to identify improvements in overall system performance and efficiency. This numerical study conducts a comprehensive thermal analysis of parabolic trough solar collectors by comparing a rhombus-shaped absorber with a conventional circular absorber.
View Article and Find Full Text PDFSci Rep
December 2024
Division of Advanced Electrical and Electronics Engineering, Tokyo University of Agriculture and Technology, 2- 24-16 Naka-cho, Koganei-shi, Tokyo, 184-8588, Japan.
A hyperbolic metamaterial absorber has great potential for improving the performance of photo-thermoelectric devices targeting heat sources owing to its broadband absorption. However, optimizing its geometry requires considering numerous parameters to achieve absorption that aligns with the radiation spectrum. Here, we compare three algorithms using deep reinforcement learning for the optimization of a hyperbolic metamaterial absorber.
View Article and Find Full Text PDFJACS Au
December 2024
Department of Chemistry, University of Connecticut, Storrs, Connecticut 06269-3060, United States.
Red-light absorbing photoredox catalysts offer potential advantages for large-scale reactions, expanding the range of usable substrates and facilitating bio-orthogonal applications. While many red-light absorbing/emitting fluorophores have been developed recently, functional red-light absorbing photoredox catalysts are scarce. Many photoredox catalysts rely on long-lived triplet excited states (triplets), which can efficiently engage in single electron transfer (SET) reactions with substrates.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!