Background: Multiple strategies have advocation for power titration and catheter movement during atrial fibrillation (AF) ablation. Comparative favoring evidence regarding the efficacy, logistics, and safety of a higher-power, shorter duration (HPSD) ablation strategy compared to a lower-power, longer duration (LPLD) ablation strategy is insubstantial. We performed a meta-analysis to compare arrhythmia-free survival, procedure times, and complication rates between the two strategies.

Methods: We searched MEDLINE, EMBASE, and Cochrane Library from inception to September 2020. We included studies comparing patients who underwent HPSD and LPLD strategies for AF ablation and reporting either of the following outcomes: Freedom from atrial tachyarrhythmia (AT) including AF and atrial flutter, procedure time, or periprocedural complications. We combined data using the random-effects model to calculate the odds ratio (OR) and weight mean difference (WMD) with a 95% confidence interval (CI).

Results: Ten studies from 2006 to 2020 involving 2274 patients were included (1393 patients underwent HPSD strategy and 881 patients underwent LPLD strategy). HPSD strategy was not associated with increased freedom from AT at 12-month follow-up (OR = 1.54, 95% CI: 0.99 to 2.40, p = .054). In the subgroup analysis of the randomized controlled trial, the HPSD strategy was associated with increased freedom from AT compared to the LPLD strategy (OR = 3.12, 95% CI: 1.18 to 8.20, p = .02). There was a significant reduction in the HPSD group for the total procedure (WMD = 49.60, 95% CI: 29.76 to 69.44) and ablation (WMD = 17.92, 95% CI: 13.63 to 22.22) times, but not for fluoroscopy time (WMD = 1.15, 95% CI: -0.67 to 2.97). HPSD was not associated with a reduction in esophageal ulcer/atrioesophageal fistula (OR = 0.35, 95% CI: 0.12 to 1.06) or pericardial effusion/cardiac tamponade rates (OR = 1.16, 95% CI: 0.35 to 3.81).

Conclusions: When compared to the LPLD strategy, the HPSD strategy does not improve recurrent AT nor reduce periprocedural complication risks. However, subgroup analysis of the randomized controlled trial showed that HPSD significantly reduces AT recurrence. An HPSD strategy can significantly reduce total procedure and ablation times.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jce.14806DOI Listing

Publication Analysis

Top Keywords

hpsd strategy
20
patients underwent
12
lpld strategy
12
hpsd
10
strategy
10
atrial fibrillation
8
fibrillation ablation
8
ablation strategy
8
underwent hpsd
8
95%
8

Similar Publications

Background: The optimal radiofrequency application (RFa) parameters for safe and durable pulmonary vein isolation (PVI) are debated. High-power short-duration (HPSD) has been used as an alternative to conventional power delivery (CPD).

Objectives: This study sought to compare HPSD 70 W/9-10 s (HPSD-70) with CPD 25-40 W in patients undergoing PVI.

View Article and Find Full Text PDF

Introduction: The suitability of high-power short-duration (HPSD) cavo-tricuspid isthmus ablation (CTI-Abl) for electrophysiology (EP) trainees, as well as the underlying mechanisms of its efficacy, remain unknown. The aim of this study was to clarify the efficacy and safety of HPSD CTI-Abl performed by EP trainees and assess lesion characteristics between HPSD and moderate-power long duration (MPLD) ablations.

Methods: Study 1: CTI-Abl was performed by first- to fourth-year EP trainees in consecutive 113 patients (67 ± 11 years, 27.

View Article and Find Full Text PDF

Introduction: In atrial fibrillation (AF) ablation, fluoroscopy has been a standard tool for catheter guidance. However, the combination of electroanatomic mapping systems (EAMs) and intracardiac echocardiography (ICE) now allows for minimal or zero-fluoroscopy procedures. Concurrently, high-power short-duration (HPSD) ablation has emerged as a promising technique, offering enhanced resistive heating while reducing conductive heating.

View Article and Find Full Text PDF

Atrial fibrillation (AF) is the most common heart rhythm disorder worldwide. As treatment methods evolve, optimizing personalized therapy based on patient characteristics, such as sex, becomes crucial. This study investigates sex differences in high-power short-duration (HPSD) pulmonary vein isolation (PVI) in overweight and obese patients.

View Article and Find Full Text PDF
Article Synopsis
  • The peQasus study evaluates the safety and effectiveness of a new temperature-controlled high-power short-duration (HPSD) radiofrequency catheter (QDOT Micro) for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF).
  • Conducted across 15 centers in Europe, the study involved 1,023 patients and compared outcomes between a very HPSD technique and a hybrid approach.
  • Results indicated complete PVI success, a mean procedure time of about 98 minutes, and a similar safety profile for both techniques, with 12-month arrhythmia-free survival rates around 77%.
View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!