A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Minimally invasive anterior plate osteosynthesis of the distal radius: A 710 case-series. | LitMetric

Minimally invasive anterior plate osteosynthesis of the distal radius: A 710 case-series.

Orthop Traumatol Surg Res

Department of hand surgery, SOS Hand, University Hospital of Strasbourg, FMTS, University of Strasbourg, Icube CNRS 7357, 1, avenue Molière, 67000 Strasbourg, France. Electronic address:

Published: December 2020

Introduction: Since the 2000s, internal fixation of distal radius fracture by volar locking plate on an extended flexor carpi radialis (FCR) approach has become the gold standard.

Objective: The present study aimed to assess medium-term results of minimally invasive plate osteosynthesis (MIPO) in distal radius fracture.

Material And Methods: The series comprised of 710 cases (512 female; mean age, 58 years). The 15mm approach was on the lateral edge of the FCR. The plate was slipped under the pronator quadratus. Closure used intradermal running suture without drain or orthosis.

Results: At a mean 7 months' follow-up, mean scar length was 17mm (range, 10-40mm), pain 1.13/10 (0-8), Quick-DASH 13.28 (0-86.36), and patient-rated wrist evaluation (PRWE) 11.48 (0-91). Compared to contralateral values, mean flexion was 87.23%, extension 88.52%, pronation 96.17%, supination 93.41%, and grip strength 79.68%. Hardware was removed in 45.92% of cases. There were 16 cases of secondary displacement, with 4 revision procedures, one of sepsis at 6 months, 10 of complex regional pain syndrome, and 14 of median nerve paresthesia, with 4 carpal tunnel release procedures.

Discussion: The minimally invasive FCR approach can be used for volar plate fixation of distal radial fracture. It has the advantage of conserving ligamentotaxis, facilitating reduction and improving scar esthetics. The incision can be extended if need be.

Level Of Evidence: III; single-centre retrospective study.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.otsr.2020.04.024DOI Listing

Publication Analysis

Top Keywords

minimally invasive
12
distal radius
12
plate osteosynthesis
8
fixation distal
8
fcr approach
8
plate
5
invasive anterior
4
anterior plate
4
distal
4
osteosynthesis distal
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!