Aims: To evaluate inter- and intrarater reliability of unidigital and bidigital vaginal palpation of pelvic floor muscle (PFM) maximal voluntary contraction (MVC) according to PFM risk factors and dysfunctions.

Methods: A total of 187 women were recruited and evaluated by two examiners. Both performed the evaluation of MVC with unidigital and bidigital palpation, graded by Modified Oxford Scale. After 7-10 days, one examiner repeated the assessment. To analyze reliability by Cohen's linear Kappa (κw), participants were allocated into different groups according to: body mass index (BMI), menopause, parity, type of delivery and PFM dysfunctions, as pelvic organ prolapse (POP), constipation, urgency, urgency urinary incontinence, pelvic pain, and stress urinary incontinence.

Results: Inter-rater reliability of unidigital palpation was considered fair (κw = 0.21-0.40) to moderate (κw = 0.41-0.60) according to BMI, postmenopausal status, parity, type of delivery, and PFM dysfunctions. Inter-rater reliability of bidigital palpation varied from none (κw = 0.00-0.20) to moderate for all risk factors and PFM dysfunctions. Intra-rater reliability of unidigital palpation was considered fair only for women with POP (κw = 0.37) and moderate to substantial (κw = 0.61-0.80) to all other variables. Intra-rater reliability of bidigital palpation ranged from moderate to almost perfect (κw = 0.81-1.00).

Conclusions: When performing vaginal palpation, physiotherapists must consider the way that is performing the evaluation, as some PFM risk factors and dysfunctions could influence the inter- and intrarater reliability of unidigital and bidigital palpation.

Download full-text PDF

Source
http://dx.doi.org/10.1002/nau.24566DOI Listing

Publication Analysis

Top Keywords

reliability unidigital
20
unidigital bidigital
16
risk factors
16
bidigital palpation
16
inter- intrarater
12
intrarater reliability
12
vaginal palpation
12
pfm dysfunctions
12
palpation
9
reliability
8

Similar Publications

Reliability of the PERFECT scheme assessed by unidigital and bidigital vaginal palpation.

Int Urogynecol J

December 2021

Physical Therapy Department, Women's Health Research Laboratory, Rodovia Washington Luís, km 235, Monjolinho, São Carlos, SP, 13565-905, Brazil.

Introduction And Hypothesis: The aim of the present study was to evaluate the inter- and intra-rater reliability of the PERFECT scheme assessed by uni- and bidigital vaginal palpation in young nulligravid women.

Methods: Forty healthy women [median age 22 (19-34) years] were evaluated by unidigital vaginal palpation by both Examiners A and C, while the other 40 participants [median age 23.5 (19-35) years] were assessed by Examiners B and C by bidigital vaginal palpation.

View Article and Find Full Text PDF

Aims: To evaluate inter- and intrarater reliability of unidigital and bidigital vaginal palpation of pelvic floor muscle (PFM) maximal voluntary contraction (MVC) according to PFM risk factors and dysfunctions.

Methods: A total of 187 women were recruited and evaluated by two examiners. Both performed the evaluation of MVC with unidigital and bidigital palpation, graded by Modified Oxford Scale.

View Article and Find Full Text PDF

Aims: Evaluate the intra- and inter-rater reliability of maximal voluntary contraction (MVC) of pelvic floor muscle (PFM) assessment by unidigital and bidigital vaginal palpation. As a secondary aim, evaluate the construct validity of vaginal palpation and a manometer.

Methods: A total of 120 women were recruited and allocated into three groups according to age (group 1 [G1]: 18-35; G2: 36-59; G3: ≥60 years).

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!