Aim: To evaluate techniques for assessing soft tissue alterations at implant sites and compare the traditionally utilized methods to the newer three-dimensional technologies emerging in the literature.

Materials And Methods: A comprehensive search was performed to identify interventional studies reporting on volumetric changes at implant sites following different treatments.

Results: Seventy-five articles were included the following: 30 used transgingival piercing alone, one utilized calliper, six with ultrasonography, six on cone-beam computed tomography, and 32 utilized optical scanning and digital technologies. Optical scanning-based digital technologies were the only approach that provided 'volumetric changes,' reported as volumetric variation in mm , or the mean distance between the surfaces/mean thickness of the reconstructed volume. High variability in the digital analysis and definition of the region of interest was observed. All the other methods reported volume variation as linear dimensional changes at different apico-coronal levels. No studies compared volumetric changes with different approaches.

Conclusions: Despite the emergence of optical scanning-based digital technologies for evaluating volumetric changes, a high degree of variation exists in the executed workflow, which renders the comparison of study results not feasible. Establishment of universal guidelines could allow for volumetric comparisons among different studies and treatments.

Download full-text PDF

Source
http://dx.doi.org/10.1111/jcpe.13401DOI Listing

Publication Analysis

Top Keywords

volumetric changes
16
digital technologies
16
implant sites
12
optical scanning-based
12
scanning-based digital
12
changes implant
8
volumetric
6
digital
5
technologies
5
sites systematic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!