Background: Catheter ablation is increasingly being performed worldwide for atrial fibrillation (AF). However, there are concerns of lower success rates and higher complications of AF ablations performed in low-volume centers. Thus, we sought to evaluate the safety and efficacy of AF catheter ablation in a low-volume center using contemporary technologies.

Methods And Results: 71 consecutive patients (50 paroxysmal AF [pAF] vs 21 persistent AF) who underwent first catheter ablation were studied. Primary outcome was AF recurrence rate. Secondary outcomes included periprocedural complications, hospitalization for symptomatic tachy-arrhythmias post-ablation and number of repeat ablations. Mean age of our cohort was 59.1 ± 9.7 years, of which 56 (78.9%) were males. 1-year AF recurrence was 19.5% in pAF and 23.8% in persistent AF (p = 0.694). Ablation in persistent AF group required longer procedural (197.76 ± 48.60 min [pAF] vs 238.67 ± 70.50 min [persistent AF], p = 0.006) and ablation duration (35.08 ± 15.84 min [pAF] vs 52.65 ± 28.46 min [persistent AF], p = 0.001). There were no significant differences in secondary outcomes. Major periprocedural complication rate was 2.8%.Subset analysis on (i) cryoablation vs radiofrequency, (ii) Ensite vs CARTO navigational system and (iii) circular vs high density mapping catheter did not yield significant differences in primary or secondary outcomes.

Conclusions: The AF ablation complication and recurrence free rates in both paroxysmal and persistent AF at one year were comparable to high-volume centers. Long-term follow up is needed. In addition, first AF catheter ablation in a low-volume center is realistic with comparable efficacy and safety outcomes to high-volume centers using contemporary ablation technologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7591346PMC
http://dx.doi.org/10.1016/j.ijcha.2020.100661DOI Listing

Publication Analysis

Top Keywords

catheter ablation
20
low-volume center
12
atrial fibrillation
8
center contemporary
8
ablation
8
ablation low-volume
8
secondary outcomes
8
[persistent af]
8
high-volume centers
8
catheter
6

Similar Publications

A Nomogram utilizing ECG P-wave parameters to predict recurrence risk following catheter ablation in paroxysmal atrial fibrillation.

J Cardiothorac Surg

January 2025

Department of Cardiology, Fujian Medical University Union Hospital, Fujian Heart Medical Center, Fujian Institute of Coronary Heart Disease, Fujian Clinical Medical Research Center for Heart and Macrovascular Disease, Fuzhou, 350001, China.

Objective: The objective of this study is to assess the predictive utility of perioperative P-wave parameters in patients with paroxysmal atrial fibrillation (PAF) undergoing catheter ablation, and to develop a predictive model using these parameters.

Methods: A total of 213 patients with PAF undergoing catheter ablation were retrospectively analyzed. P-wave parameters were measured within 3 days preoperatively and on the day postoperatively to determine their predictive significance for postoperative PAF recurrence.

View Article and Find Full Text PDF

Background: Atrial fibrillation (AF) is the most prevalent arrhythmia encountered in clinical practice. Triglyceride glucose index (Tyg), a convenient evaluation variable for insulin resistance, has shown associations with adverse cardiovascular outcomes. However, studies on the Tyg index's predictive value for adverse prognosis in patients with AF without diabetes are lacking.

View Article and Find Full Text PDF

This study aims to improve the quality of clinical treatment and nursing care to standardize perioperative management for patients with liver tumors undergoing co-ablation system therapy. The Committee of Ablation Therapy in Oncology, China Anti-Cancer Association; the Expert Committee on Ablation Therapy; Chinese Society of Clinical Oncology (CSCO); and the Committee of Interventional, Perioperative, and Interventional Physician Branch of Chinese Medical Doctors Association organized medical and nursing experts in China. Based on the clinical practice of co-ablation system therapy in China and relevant domestic literature, an expert consensus about perioperative management was developed.

View Article and Find Full Text PDF

Introduction: Electrophysiologic (EP) procedures are typically performed via the femoral venous system, but in some patients, the inferior vena cava (IVC) is unavailable. The hepatic vein has emerged as a viable alternative to femoral access, providing an inferior route that accommodates large sheaths required for better catheter manipulation. Although the percutaneous transhepatic approach has been used successfully in the pediatric population, its use in adults is scarce, with a complication rate of approximately 5%.

View Article and Find Full Text PDF

Introduction: Suture-mediated vascular closure devices have been widely used in catheter ablation, with 0.14-0.3 % incidence of pseudoaneurysm complications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!