Objective: The authors aim to compare all code blue events, regardless of the need for chest compressions, in the neonatal intensive care unit (NICU) versus the pediatric intensive care unit (PICU). We hypothesize that code events in the two units differ, reflecting different disease processes.

Study Design: This is a retrospective analysis of 107 code events using the code narrator, which is an electronic medical record of real-time code documentation, from April 2018 to March 2019. Events were divided into two groups, NICU and PICU. Neonatal resuscitation program algorithm was used for NICU events and a pediatric advanced life-support algorithm was used for PICU events. Events and outcomes were compared using univariate analysis. The Mann-Whitney test and linear regressions were done to compare the total code duration, time from the start of code to airway insertion, and time from airway insertion to end of code event.

Results: In the PICU, there were almost four times more code blue events per month and more likely to involve patients with seizures and no chronic condition. NICU events more often involved ventilated patients and those under 2 months of age. The median code duration for NICU events was 2.5 times shorter than for PICU events (11.5 vs. 29 minutes), even when adjusted for patient characteristics. Survival to discharge was not different in the two groups.

Conclusion: Our study suggests that NICU code events as compared with PICU code events are more likely to be driven by airway problems, involve patients <2 months of age, and resolve quickly once airway is taken care of. This supports the use of a ventilation-focused neonatal resuscitation program for patients in the NICU.

Key Points: · Code blue events are four times more common in PICU.. · NICU code events are 2.5 times shorter in duration compared with PICU events.. · NICU code events are more likely to be attributed to a problem with an airway..

Download full-text PDF

Source
http://dx.doi.org/10.1055/s-0040-1719116DOI Listing

Publication Analysis

Top Keywords

code events
16
events
14
code
13
code blue
12
blue events
12
intensive care
12
nicu events
12
pediatric intensive
8
care unit
8
picu events
8

Similar Publications

Objectives: The purpose of this study was to determine the accuracy of the Relative Value Update Committee (RUC) and Centers for Medicare & Medicaid Services current times and work relative value units (wRVUs) for the perioperative work involved in anterior cruciate ligament (ACL) reconstruction by directly timing perioperative tasks as they occur in real time.

Methods: The RUC was contacted to obtain a list of perioperative tasks and the corresponding times allotted for the tasks involved in arthroscopically aided ACL reconstruction (Current Procedural Terminology code 29888). The tasks that occurred both inside and outside the operating room were timed by the attending physician as the event occurred.

View Article and Find Full Text PDF

Background: The immune response to infections may become dysregulated and promote myocardial damage contributing to heart failure (HF). We examined the relationship between infection-related hospitalization (IRH) and HF, HF with preserved ejection fraction, and HF with reduced ejection fraction.

Methods And Results: We studied 14 468 adults aged 45 to 64 years in the ARIC (Atherosclerosis Risk in Communities) Study who were HF free at visit 1 (1987-1989).

View Article and Find Full Text PDF

To analyze nationwide pre-operative gonioscopy utilization patterns for various glaucoma surgeries and laser surgeries over time using the IRIS Registry (Intelligent Research in Sight). Retrospective cohort study. All adults who underwent a glaucoma surgery or laser surgery between January 1, 2014 and April 14, 2023.

View Article and Find Full Text PDF

Gold nanoparticles can exhibit unique physical and chemical properties, such as plasmon resonances or photoluminescence. These nanoparticles have many atoms, which leads to high computational costs for density functional theory (DFT) calculations. In this work, we used the FLARE++ (fast learning of atomistic rare events) code and incorporated an active learning algorithm to construct force fields for gold thiolate-protected nanoclusters.

View Article and Find Full Text PDF

Background: Alirocumab is a fully human monoclonal antibody to proprotein convertase subtilisin kexin type 9 used for the reduction of low-density lipoprotein cholesterol (LDL-C) in high-risk patients not reaching their LDL-C target. Recently, a 2-mL prefilled autoinjector has been developed to support the monthly 300-mg dosing regimen with a single-injection administration.

Methods And Objectives: Monthly application of 300 mg AlirRocumab (Praluent) using the 2-mL SYDNEY Device (MARS) is a non-interventional, open, prospective, multi-center cohort study conducted in Germany between 2021 and 2023 with an observational period of 12 weeks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!