Purpose: The aim of this study was to evaluate the usefulness of transcatheter arterial embolization (TAE) using the triaxial system with N-butyl-2-cyanoacrylate (NBCA) for acute arterial bleeding in comparison to TAE using the triaxial system with gelatin sponges (GS) and/or coils.

Material And Methods: Between October 2013 and November 2018, 95 patients with acute arterial bleeding underwent emergency TAE using the triaxial system. Six patients underwent multiple TAEs and thus, 104 TAEs using the triaxial system were performed. In 26 of the 104 cases, TAE were performed with NBCA (NBCA group), and in the remaining 78 cases, TAE were performed with GS and/or coils (control group).

Results: Hemorrhagic shock and coagulopathy more often occurred in the NBCA group. Procedure time was shorter in the NBCA group. The technical success rate was 100% in both groups ( > 0.99). The clinical success rate in the NBCA and control groups was 92% and 96%, respectively ( = 0.6). There was one minor complication (4%, 1/26) of liver dysfunction in a patient of the NBCA group, but no complication in the control group ( = 0.26).

Conclusion: TAE using the triaxial system with NBCA may be useful for acute arterial bleeding, especially in patients with hemorrhagic shock and coagulopathy.

Download full-text PDF

Source
http://dx.doi.org/10.1080/13645706.2020.1830801DOI Listing

Publication Analysis

Top Keywords

triaxial system
24
acute arterial
16
arterial bleeding
16
tae triaxial
16
nbca group
16
nbca
8
nbca acute
8
cases tae
8
tae performed
8
hemorrhagic shock
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!