A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Prostate or bone? Comparing the efficacy of image guidance surrogates for pelvis and prostate radiotherapy using accumulated delivered dose. | LitMetric

Prostate or bone? Comparing the efficacy of image guidance surrogates for pelvis and prostate radiotherapy using accumulated delivered dose.

J Med Imaging Radiat Sci

Radiation Medicine Program, Princess Margaret Cancer Centre, Department of Radiation Oncology, University of Toronto, Toronto, Canada.

Published: March 2021

Introduction: This study assessed the impact of dosimetry to both the target and normal tissue when either bony anatomy (BA) or prostate (PRO) was used as surrogates for image guidance for pelvis and prostate radiotherapy using a dose accumulation process.

Methods: Thirty patients who were prescribed 50-54Gy to the pelvic lymph nodes (PLN) and 78Gy to the prostate/seminal vesicles were included. Daily acquired CBCTs were rigidly registered to the CT using BA and PRO to simulate two different treatment positions. The accumulated delivered dose (D) of PLN, prostate, bladder and rectum for each surrogate were compared with the planned dose. Deviation from the planned dose (ΔD) of >5% was considered clinically significant.

Results: Prostate was displaced from bony anatomy by > 5 mm in 96/755 fractions (12.7%). Deviation between the mean D and the planned dose for PLN and prostate was <2% when either BA or PRO was used. No significant deviation from planned dose was observed for bladder (p > 0.2). In contrary, D for rectum D was significantly greater than the planned dose when BA was used (Mean ΔD = 6%). When examining individual patient, deviation from the planned dose for rectum D was clinically significant for 18 patients for BA (Range: 5-21%) and only 8 patients for PRO (Range: 5-8%).

Conclusions: The use of either BA or PRO for image guidance could deliver dose to PLN and prostate with minimal deviation from the plan using existing PTV margins. However, deviation for rectum was greater when BA was used.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmir.2020.10.001DOI Listing

Publication Analysis

Top Keywords

planned dose
20
image guidance
12
dose pln
12
pln prostate
12
deviation planned
12
dose
9
prostate
8
pelvis prostate
8
prostate radiotherapy
8
accumulated delivered
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!