A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Computational fluid dynamics of internal mammary artery-left anterior descending artery anastomoses. | LitMetric

Objectives: The aim of this study was to elucidate the remodelling of the internal mammary artery (IMA)-left anterior descending artery anastomosis and compare 2 different anastomosis techniques (end-to-side versus side-to-side) using computational fluid dynamics.

Methods: This study included 9 patients. Computed tomography (CT) angiography was performed immediately after coronary artery bypass grafting (CABG) and at 3-6 months later. The computational fluid dynamics models were made using the CT data. The pulsatile 3-dimensional blood flow was achieved with the finite volume method to evaluate the postoperative morphological and haemodynamic changes at the anastomosis in each patient. Flow velocity distribution, wall shear stress (WSS) and its fluctuation oscillatory shear index were measured.

Results: No early or mid-term graft occlusion was observed in the study series. In the side-to-side anastomosis, pouch formation at the distal end of IMA caused a vortex flow with low WSS immediately after CABG. However, at 3-6 months after surgery, this pouch disappeared. As a result, the laminar straight flow with uniform WSS distribution was achieved inside the anastomosis. In the end-to-side anastomosis, the anastomosis shape was remodelled, resulting in a laminar flow pattern with uniform WSS distribution. A patchy high oscillatory shear index was detected at the IMA wall on the top of anastomosis in either anastomosis techniques immediately after the surgery, but it disappeared at 3-6 months after surgery.

Conclusions: Regardless of the anastomosis technique used, a successful remodelling of the IMA-left anterior descending artery anastomosis shape was achieved a few months after surgery, resulting in a straightforward flow streamline, with uniform WSS distribution and minimal oscillatory shear index.

Download full-text PDF

Source
http://dx.doi.org/10.1093/icvts/ivaa183DOI Listing

Publication Analysis

Top Keywords

computational fluid
12
anterior descending
12
descending artery
12
oscillatory shear
12
uniform wss
12
wss distribution
12
anastomosis
11
fluid dynamics
8
internal mammary
8
ima-left anterior
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!