Introduction: A key component to analyzing wearable sensor data is identifying periods of non-wear. Traditionally, strings of consecutive zero counts (e.g. >60-minutes) are identified indicating periods of non-movement. The non-movement window length is then evaluated as wear or non-wear. Given that non-movement is not equivalent to non-wear, additional criteria should be evaluated to objectively identify periods of non-wear. Identifying non-wear is especially challenging in infants due to their sporadic movement, sleep frequency, and proportion of caregiver-generated movement.
Purpose: To use hip- and ankle-worn ActiGraph wGT3X-BT (wGT3X-BT) data to identify non-wear in infants.
Methods: Fifteen infant participants [mean±SD; age, 8.7±1.7 weeks (range 5.4-11.3 weeks); 5.1±0.8 kg; 56.2±2.1 cm; n = 8 females] wore a wGT3X-BT on the hip and ankle. Criterion data were collected during two, 2-hour directly observed periods in the laboratory. Using raw 30 Hz acceleration data, a vector magnitude and the inclination angle of each individual axis were calculated before being averaged into 1-minute windows. Three decision tree models were developed using data from 1) hip only, 2) ankle only, and 3) hip and ankle combined.
Results: The hip model classified 86.6% of all minutes (wear and non-wear) correctly (F1 = 75.5%) compared to the ankle model which classified 90.6% of all minutes correctly (F1 = 83.0%). The combined site model performed similarly to the ankle model and correctly classified 90.0% of all minutes (F1 = 80.8%).
Conclusion: The similar performance between the ankle only model and the combined site model likely indicates that the features from the ankle device are more important for identifying non-wear in infants. Overall, this approach provides an advancement in the identification of device wear status using wearable sensor data in infants.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7605692 | PMC |
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0240604 | PLOS |
Sensors (Basel)
December 2024
Assessment of Movement Behaviours (AMBer), Leicester Lifestyle and Health Research Group, Diabetes Research Centre, University of Leicester, Leicester LE5 4PW, UK.
Background: Following shoulder surgery, controlled and protected mobilisation for an appropriate duration is crucial for appropriate recovery. However, methods for objective assessment of sling wear and use in everyday living are currently lacking. In this pilot study, we aim to determine if a sling-embedded triaxial accelerometer and/or wrist-worn sensor can be used to quantify arm posture during sling wear and adherence to sling wear.
View Article and Find Full Text PDFBurns
February 2025
Alliance of Dutch Burn Centers, Burn Center Martini Hospital Groningen, Groningen, the Netherlands; Hanze University of Applied Sciences Groningen, Research Group Healthy Ageing, Allied Healthcare and Nursing, Groningen, the Netherlands; University of Groningen, University Medical Center Groningen, Department of Human Movement Sciences, Groningen, the Netherlands. Electronic address:
Biomimetics (Basel)
November 2024
Research Institute, Hospital for Special Surgery, New York, NY 10021, USA.
Background: The current murine models of peri-implant osseointegration failure are associated with wear particles. However, the current clinical osseointegration failure is not associated with wear particles. Here, we develop a murine model of osseointegration failure not associated with wear particles and validate it by comparing the cellular composition of interfacial tissues with human samples collected during total joint arthroplasty revision for aseptic loosening.
View Article and Find Full Text PDFPLoS One
October 2024
Department of Health and Sport Sciences, Graduate School of Medicine, Osaka University, Toyonaka, Osaka, Japan.
Wearable devices are increasingly utilized to monitor physical activity and sedentary behaviors. Accurately determining wear/non-wear time is complicated by zero counts, where the acceleration-based indexes do not estimate activity intensity, often leading to misclassifications. We propose a novel synthetic classification algorithm that leverages both the probability and continuity of zero counts, aiming to enhance the accuracy of activity estimation.
View Article and Find Full Text PDFEur Rev Aging Phys Act
October 2024
Epidemiology of Ageing and Neurodegenerative Diseases, Université Paris Cité, INSERM, U1153, CRESS, 10 Avenue de Verdun, Paris, 75010, France.
Background: A more fragmented, less stable rest-activity rhythm (RAR) is emerging as a risk factor for health. Accelerometer devices are increasingly used to measure RAR fragmentation using metrics such as inter-daily stability (IS), intradaily variability (IV), transition probabilities (TP), self-similarity parameter (α), and activity balance index (ABI). These metrics were proposed in the context of long period of wear but, in real life, non-wear might introduce measurement bias.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!