Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 143
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 143
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 209
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3098
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Severity: Warning
Message: Attempt to read property "Count" on bool
Filename: helpers/my_audit_helper.php
Line Number: 3100
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3100
Function: _error_handler
File: /var/www/html/application/controllers/Detail.php
Line: 574
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 488
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background And Purpose: Magnetic Resonance (MR)-only planning has been implemented clinically for radiotherapy of prostate cancer. However, fewer studies exist regarding the overall success rate of MR-only workflows. We report on successes and challenges of implementing MR-only workflows for prostate.
Materials And Methods: A total of 585 patients with prostate cancer underwent an MR-only simulation and planning between 06/2016-06/2018. MR simulation included images for contouring, synthetic-CT generation and fiducial identification. Workflow interruptions occurred that required a backup CT, a re-simulation or an update to our current quality assurance (QA) process. The challenges were prospectively evaluated and classified into syn-CT generation, motion/artifacts in the MRs, fiducial QA and bowel preparation guidelines.
Results: MR-only simulation was successful in 544 (93.2 %) patients. . In seventeen patients (2.9%), reconstruction of synthetic-CT failed due to patient size, femur angulation, or failure to determine the body contour. Twenty-four patients (4.1%) underwent a repeat/backup CT scan because of artifacts on the MR such as image blur due to patient motion or biopsy/surgical artifacts that hampered identification of the implanted fiducial markers. In patients requiring large coverage due to nodal involvement, inhomogeneity artifacts were resolved by using a two-stack acquisition and adaptive inhomogeneity correction. Bowel preparation guidelines were modified to address frequent rectum/gas issues due to longer MR scan time.
Conclusions: MR-only simulation has been successfully implemented for a majority of patients in the clinic. However, MR-CT or CT-only pathway may still be needed for patients where MR-only solution fails or patients with MR contraindications.