Objective: This study aimed to peruse anatomic features of the cranial aperture of the optic canal (CAOC) for obtaining an extended morphometric dataset in children.
Methods: Computed tomography images of 200 children were included in this retrospective work to analyze the shape, location and diameters of the CAOC.
Results: The CAOC area, width and height were observed as 17.53 ± 2.80 mm, 6.12 ± 0.84 mm, and 4.35 ± 0.64 mm, respectively. The angle of the optic canal in axial plane was found as 39.28 ± 5.13°, while in sagittal plane as 16.01 ± 6.76°. The distance between the CAOC and the midsagittal line was 7.17 ± 1.48 mm. The CAOC was measured as 54.04 ± 5.23 mm and 42.55 ± 3.28 mm away from the anterior and lateral boundary of the anterior skull base, respectively. The CAOC shape was described as the tear-drop (186 foramina, 46.5%), triangular (156 foramina, 39%), oval (47 foramina, 11.8%), and round (11 foramina, 2.8%).
Conclusion: The depth, angle and diameter measurements belonging to the CAOC were changing according to its shape or demographic data (e.g., sex and age). Therefore, preoperative radiologic evaluation containing the shape, location and size of the CAOC should be considered by multidisciplinary operating teams in terms of surgical interventions such as implant positioning.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00276-020-02604-6 | DOI Listing |
J Imaging
December 2024
Department of Orthopedic Research, Arthrex, 81249 Munich, Germany.
Objective: This study evaluated the effect of three-dimensional (3D) volumetric humeral canal fill ratios (VFR) of reverse shoulder arthroplasty (RSA) short and standard stems on biomechanical stability and bone deformations in the proximal humerus.
Methods: Forty cadaveric shoulder specimens were analyzed in a clinical computed tomography (CT) scanner allowing for segmentation of the humeral canal to calculate volumetric measures which were verified postoperatively with plain radiographs. Virtual implant positioning allowed for group assignment (VFR < 0.
Sci Rep
December 2024
Department of Physics, Faculty of Science, Menoufia University, Shebin El-Koom, Menoufia, 32511, Egypt.
Barium fluoride borosilicate glass samples reinforced with varying amounts of GdO (BSBLG0-BSBLG4) have been manufactured using the conventional melt quenching procedure in order to provide additional research on the type of borosilicate glass. Structural, physical, and linear optical characteristics as well as γ-ray attenuation capacity of barium fluoride borosilicate doped with GdO was investigated. X-ray diffraction pattern proving the amorphous nature of the glass samples due to the absence of a distinctive crystalline characteristic peak.
View Article and Find Full Text PDFExp Eye Res
December 2024
Department of Ophthalmology, Faculty of Life Sciences, Kumamoto University, Kumamoto, Japan.
Intraocular pressure (IOP) is regulated through the balance of production and drainage of aqueous humor. The main route of aqueous-humor outflow comprises the trabecular meshwork (TM) and Schlemm's canal (SC). We reported that IL-6 trans-signaling can inhibit TGF-β signaling in TM cells and may affect regulation of IOP.
View Article and Find Full Text PDFRadiother Oncol
December 2024
Department of Radiation Oncology, Eye & ENT Hospital, Fudan University, Shanghai, China. Electronic address:
Aim: We aimed to examine the influence of various prognostic factors on the outcome of external auditory canal (EAC) cancer and create a graphical prediction tool, marking a first in this field, premised on these determinants.
Methods: We retrospectively analysed 173 patients with EAC cancer, making this the largest patient cohort in the literature. Survival analysis was performed using the Kaplan-Meier method, and the log-rank test was used to assess the differences between established prognostic variables.
J Fr Ophtalmol
December 2024
Biostatistics and Research Methodology Unit, School of Medical Sciences, Health Campus, University Sains Malaysia, Kubang Kerian 16150, Kelantan, Malaysia.
Purpose: To correlate fluorescein dye disappearance test (FDDT) grades and endoscopic dye transit times (EDTT) in patients with patent osteotomies after nasolacrimal duct obstruction surgery (NLDO).
Design: Cross-sectional study.
Methods: All adult patients with patent osteotomies post-external dacryocystorhinostomy (Ex-DCR) or post-endoscopic dacryocystorhinostomy (EDCR) for NLDO were included in this cross-sectional investigation.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!