Radiographic goniometry of the PIP-joint: A reliable measurement method.

J Hand Ther

Department of Plastic, Reconstructive and Hand Surgery, Isala Hospital, Zwolle, The Netherlands.

Published: December 2021

Introduction: Arthrodesis of the proximal interphalangeal joint (PIP joint) is a good treatment option for relief of arthritic pain. The angle of the fused PIP joint is considered important for postoperative digital function. It is therefore important to reliably measure the actual angle of fusion. Goniometry performed by hand therapists or hand surgeons can generate measurement errors.

Purpose Of The Study: The purpose of this study is therefore to investigate the intraobserver and interobserver reliability of measuring the angle of fusion of the PIP joint on X-rays.

Study Design: A clinimetric study was conducted investigating the reliability of X-ray goniometry.

Methods: Three blinded observers measured the angle of the PIP-joint fusion on a lateral postoperative X-ray. The intraobserver and interobserver reliability was calculated.

Results: Ninety-four patient X-rays were measured. The intraobserver reliability showed an intraclass correlation coefficient (ICC) of 0.94, and the ICC for the interobserver reliability ranged between 0.92 and 0.95.

Discussion: Because this is the first reliability study on radiographic goniometry, comparison of our data with other similar studies is difficult. The best comparison can be made to in vivo goniometry. Based on the investigation of ICC values of various studies on the reliability of in vivo goniometry, radiographic goniometry seems to be more reliable.

Conclusions: These results indicate an excellent reliability, which is generally higher than the reliability for in vivo goniometry of the PIP joint performed by hand therapists or hand surgeons. We can conclude that radiographic goniometry of the PIP joint is a highly reliable measurement method.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jht.2020.08.002DOI Listing

Publication Analysis

Top Keywords

pip joint
20
radiographic goniometry
16
interobserver reliability
12
vivo goniometry
12
reliability
9
reliable measurement
8
measurement method
8
angle fusion
8
performed hand
8
hand therapists
8

Similar Publications

Finger reconstruction with vascularized partial osteo-onycho-cutaneous great toe transfer: It's time to address the donor site.

J Hand Microsurg

March 2025

Department of Plastic, Cosmetic, Hand and Microsurgery, Sir Ganga Ram Hospital, Room No. 2325, 3rd Floor, SSRB Building, New Delhi, 110060, India.

Free vascularized partial great toe is a composite tissue consisting of the osteo-onycho-cutaneous component with neurovascular pedicle and is used for reconstructing amputated fingers at different levels. The half-big-toe nail flap represents that while it provides a good match and functional results; it also conserves the donor foot by having all five toes intact. The aesthetic and functional aspects of the amputated thumbs and fingers can be worked upon and significantly improved.

View Article and Find Full Text PDF

Lateral band snapping syndrome can be a debilitating condition involving the proximal interphalangeal (PIP) joint of the fingers. Although rare, it is thought to occur due to disruption of the finger extensor mechanism allowing inappropriate subluxation of the lateral bands over the PIP joint, leading to mechanical and painful symptoms.Here, we describe a woman in her early 40s with a painful, snapping PIP joint secondary to a work-related injury.

View Article and Find Full Text PDF

Background: Adhesion formation poses a significant challenge for both patients and hand surgeons following tendon repair. One common strategy to prevent adhesion formation is the use of physical barriers. This study aimed to compare the outcomes of extensor tendon repair with and without the application of the OrthoWrap bioresorbable Sheet, specifically in terms of adhesion prevention.

View Article and Find Full Text PDF

Volar Plate Draping (VPD) for Severely Comminuted Proximal Phalanx Head Fractures.

Indian J Plast Surg

December 2024

The Department of Plastic, Hand and Reconstructive Microsurgery, Ganga Medical Center and Hospitals, Coimbatore, Tamil Nadu, India.

While proximal phalangeal joint injuries with comminution of the base of the middle phalanx are common injuries, proximal interphalangeal (PIP) joint fracture dislocations with an intact base of middle phalanx and a comminuted head of proximal phalanx are rare. Volar plate arthroplasty and other described techniques prevail for the former injury, while the latter does not have any supportive literature on the exact method of management. We herein present a 20-year-old male with a severely comminuted head of proximal phalanx fracture with dislocation of the PIP joint, which was not reconstructable but was managed successfully with a novel technique of volar plate draping that resurfaced the raw phalangeal head.

View Article and Find Full Text PDF

Purpose: Terminal extensor tenotomy or Dolphin tenotomy, is a described treatment for the management of distal interphalangeal (DIP) joint hyperextension in chronic boutonniere deformity. The purpose of this study was to investigate the effects of incremental partial Dolphin tenotomy in correcting boutonniere deformity, with a focus on evaluating the improvement in DIP joint hyperextension deformity and documenting the development of iatrogenic mallet finger.

Methods: Thirty-eight fingers from 10 cadaveric hands were used.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!