A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Ultrasonication-facilitated synthesis of functionalized graphene oxide for ultrasound-assisted magnetic dispersive solid-phase extraction of amoxicillin, ampicillin, and penicillin G. | LitMetric

A simplistic approach is presented for the synthesis of ultrasonically fabricated graphene oxide functionalized with polyaniline and N-[3-(Trimethoxysilyl)propyl]ethylenediamine. The synthesized nanocomposite was then employed for the facile, green, ultrasound-assisted, magnetic dispersive solid-phase extraction of amoxicillin, ampicillin, and penicillin G in milk samples and infant formula prior to high-performance liquid chromatography-ultraviolet determination. The designed nanocomposites were comprehensively characterized using field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, transmission electron microscopy, X-ray powder diffraction, and Fourier transform infrared spectroscopy. In order to achieve the best extraction efficiencies, the influential parameters including pH, amount of magnetic sorbent, type and volume of elution solvent, extraction time, sample volume, and desorption time were assessed. At the optimum conditions, linear ranges of 2.5-1000 (μg L) for ampicillin and penicillin G and a linear range of 2.5-750 (μg L) were obtained for amoxicillin at optimum conditions. Moreover, the limits of detection (S/N = 3) of 0.5, 0.8, and 0.9 (μg L) were obtained for amoxicillin, ampicillin, and penicillin G, respectively. The precision (relative standard deviations (%)) values of 3.1, 2.6, and 2.5 at the concentration of 50 μg L for seven replicates were obtained for ampicillin, amoxicillin, and penicillin G, respectively. The efficiencies of ≤ 96% and relative standard deviations of less than 3.1% were also obtained thereby confirming the high potential of the synthesized nanocomposites for simultaneous preconcentration and separation of the β-lactam antibiotics in complex matrixes. Graphical Abstract.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-020-04605-zDOI Listing

Publication Analysis

Top Keywords

ampicillin penicillin
16
amoxicillin ampicillin
12
graphene oxide
8
ultrasound-assisted magnetic
8
magnetic dispersive
8
dispersive solid-phase
8
solid-phase extraction
8
extraction amoxicillin
8
electron microscopy
8
optimum conditions
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!