Aims: To investigate the dependence of blood vessel density and velocity in ophthalmic artery and arteria centralis retinae of the same eye in patients with normotensive glaucoma.

Methods: The sample consisted of 20 patients with normotensive glaucoma (NTG). There were 17 women (mean age 56.1) and 3 men (mean age 60 years). Inclusion criteria for study: visual acuity 1.0 with correction up to ±3 dioptres, approximately equal changes in the visual field, whereby it was incipient NTG and diagnosis was confirmed by electrophysiological examination, without further ocular or neurological disease. Parameters of vessel density (VD) were evaluated by Avanti RTVue XR (Optovue). Perfusion parameters such as peak systolic velocity (PSV), end diastolic velocity (EDV) and resistive index (RI) were evaluated for ophthalmic artery (AO) and arteria centralis retinae (ACR) using Doppler sonography (Affinity 70G Philips, probe 5-12 MHz). Visual field (VF) was evaluated by automated perimeter (Medmont M700) using fast threshold glaucoma strategy test. The sum of sensitivity levels in apostilb (asb) were evaluated in range 0-22 degrees of visual field. Resulting values of VF were compared with VD and perfusion parameters in AO and ACR at the same eye.

Results: Pearsons correlation coefficient was used to evaluate the dependence. Data shows, that changes in visual fields are mainly caused by peripapillary VD of small and all vessels, and vessels throughout measured image area also. Correlation of small vessels throughout measured image area was weak (r = 0.23). Moderate negative correlation was found for PSV in AO and peripapillary small VD (r = -0.46), all peripapillary VD (r = -0.49), VD in whole area (r = -0.45), then between EDV in AO and VD in whole area (r = -0.42). Other correlations between VD and perfusion parameter were insignificant.

Conclusions: Study confirms, that changes of visual field in NTG patients are mainly caused by VD rather than perfusion parameters, especially in AO. Perfusion parameters in ACR are not significantly correlated with changes of VF in NTG patients.

Download full-text PDF

Source
http://dx.doi.org/10.31348/2020/20DOI Listing

Publication Analysis

Top Keywords

visual field
16
perfusion parameters
16
changes visual
12
doppler sonography
8
vessel density
8
ophthalmic artery
8
artery arteria
8
arteria centralis
8
centralis retinae
8
patients normotensive
8

Similar Publications

The timely detection of viral pathogens in vineyards is a critical aspect of management. Diagnostic methods can be labor-intensive and may require specialized training or facilities. The emergence of artificial intelligence (AI) has the potential to provide innovative solutions for disease detection but requires a significant volume of high-quality data as input.

View Article and Find Full Text PDF

Goal-directed behavior requires the effective suppression of distractions to focus on the task at hand. Although experimental evidence suggests that brain areas in the prefrontal and parietal lobe contribute to the selection of task-relevant and the suppression of task-irrelevant stimuli, how conspicuous distractors are encoded and effectively ignored remains poorly understood. We recorded neuronal responses from 2 regions in the prefrontal and parietal cortex of macaques, the frontal eye fields (FEFs) and the lateral intraparietal (LIP) area, during a visual search task, in the presence and absence of a salient distractor.

View Article and Find Full Text PDF

Background: Crohn's disease (CD) is a chronic, recurrent gastrointestinal disorder characterized by a complex etiology. Among its perianal complications, anal fistulas represent a challenging comorbidity. With the increase of surgical options, a comprehensive bibliometric analysis was deemed necessary to consolidate the vast array of research in this field.

View Article and Find Full Text PDF

Virtual 3D reconstruction of complex congenital cardiac anatomy from 3D rotational angiography.

3D Print Med

January 2025

Department of Pediatric Cardiology, The Heart Institute, University of Colorado, Children's Hospital Colorado, 13123 E 16th Ave B100, 80045, Aurora, CO, USA.

Background: Despite advancements in imaging technologies, including CT scans and MRI, these modalities may still fail to capture intricate details of congenital heart defects accurately. Virtual 3D models have revolutionized the field of pediatric interventional cardiology by providing clinicians with tangible representations of complex anatomical structures. We examined the feasibility and accuracy of utilizing an automated, Artificial Intelligence (AI) driven, cloud-based platform for virtual 3D visualization of complex congenital heart disease obtained from 3D rotational angiography DICOM images.

View Article and Find Full Text PDF

Purpose: This study evaluates the effect of 6° horizontal gaze tolerance on visual field mean sensitivity (MS) in patients with glaucoma using a binocular head-mounted automated perimeter, following findings of structural changes in the posterior globe from magnetic resonance imaging and optical coherence tomography.

Methods: In this cross-sectional study, a total of 161 eyes (85 primary open-angle glaucoma [POAG] and 76 healthy) from 117 participants were included. Logistic regression and 1:1 matched analysis assessed the propensity score for glaucoma and healthy eyes, considering age, sex, and axial length as confounders.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!