A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Changes in Bond Strength and Topography for Y-TZP Etched with Hydrofluoric Acid Depending on Concentration and Temperature Conditions. | LitMetric

: This study aimed to investigate the change in bond strength between resin cement and tetragonal zirconia polycrystalline stabilized with 3 to 8 mol% yttrium oxide (Y-TZP) and observe the topographical change of the Y-TZP surface when etched with hydrofluoric acid (HF) solution under different concentration and temperature conditions. : Non-etched sintered Y-TZP specimens under two different temperature conditions (room temperature and 70-80 °C, respectively), were used as a control, while experimental groups were etched with 5%, 10%, 20%, and 40% HF solutions for 10 min. After zirconia primer and MDP-containing resin cement were applied to the Y-TZP surface, the shear bond strength (SBS) of each experimental group was measured. : Under room temperature conditions, the highest SBS value was measured in the 40% HF etching group, representing a significant deviation from the other groups ( < 0.05). In the 70-80 °C tests, the 40% HF etching group also had the highest SBS value, but there was no significant difference when compared to the 20% HF etching group ( > 0.05). From SEM and AFM observations, the HF solution increasingly dissolved the Y-TZP surface grain structure as the concentration and application temperature rose, resulting in high surface roughness and irregularities. : Pretreating with either 20% HF solution at 70-80 °C or 40% HF solution at room temperature and 70-80 °C effectively acid etched the Y-TZP surface, resulting in more surface roughness and irregularities. Accounting for the concentration and temperature conditions of the HF solution, using 40% HF solution at room temperature will result in improvements in adhesion between resin cement and Y-TZP.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7692792PMC
http://dx.doi.org/10.3390/medicina56110568DOI Listing

Publication Analysis

Top Keywords

temperature conditions
20
y-tzp surface
16
room temperature
16
70-80 °c
16
bond strength
12
concentration temperature
12
resin cement
12
etching group
12
temperature
9
y-tzp
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!