ANALYSIS BY SCANNER OF TRACKS PRODUCED BY RADON ALPHA PARTICLES IN CR-39 DETECTORS.

Radiat Prot Dosimetry

National Institute for Nuclear Physics (INFN), Branch of Naples, via Cintia 21, Naples 80126, Italy.

Published: November 2020

The most used passive detectors for Radon measurement are the CR39s, both for the good stability of the material and for the practicality of use. But, commercial reading systems are expensive and not always fast. The aim of the present work was the development of a method for a rapid, efficient and economic evaluation of the result of the indoor Radon measurement performed with CR39 detectors. The analysis and acquisition of detector images were performed using a photo scanner and the free ImageJ software. Several groups of CR-39 detectors were exposed, developed and analysed. Calibration curve was obtained in a wide range of exposure values (200-12 000 kBq·h·m -3) to allow the procedure to be applied in all possible measurement environments. Furthermore, a statistical study was carried out on the shape and size of nuclear tracks after chemical development. The dependence of the track size on Radon exposure was effective in showing the trace saturation effect as well.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncaa140DOI Listing

Publication Analysis

Top Keywords

cr-39 detectors
8
radon measurement
8
analysis scanner
4
scanner tracks
4
tracks produced
4
radon
4
produced radon
4
radon alpha
4
alpha particles
4
particles cr-39
4

Similar Publications

Assessment of radon level and the associated radiological risk from soil samples of quarry area at Hakim Gara, Ethiopia.

Environ Monit Assess

December 2024

School of Nuclear and Allied Sciences, University of Ghana, Atomic Campus, P.O. Box LG 80 Legon, Accra, Ghana.

Excavation of terrestrial surface of the Earth could enhance the chance of exposure to radon while gases in the underground get access to escape. This study was aimed to assess the level of radon concentration from soil samples of quarrying sites at Hakim Gara in Ethiopia using CR-39 detectors in sealed container technique. The results of the measured radon concentration level were ranging from 164.

View Article and Find Full Text PDF

Radiation Detection-CD/DVD, Glass, and Emerging Materials for Radon Exposure Assessment.

Sensors (Basel)

November 2024

Department of Environmental Health, Faculty of Health Sciences, Doornfontein Campus, University of Johannesburg, P.O. Box 524, Johannesburg 2006, South Africa.

This review aimed to explore advances in radon detection methods, emphasizing cost-effectiveness and accessible techniques such as CDs, DVDs, and glass-based detectors. In this review, we compared traditional methods like alpha track detectors and continuous radon monitors with emerging innovations that leverage polycarbonate material and IoT-integrated systems. Our evaluation of the synthesis suggests that CDs and DVDs provide scalable solutions for long-term radon monitoring, while glass-based detectors like CR-39 offer high sensitivity for epidemiological studies.

View Article and Find Full Text PDF

Total alpha radioactivity in fertilizers used in the Indian state of West Bengal using CR-39 SSNTDs: Presentation of a comparative view for different types of fertilizers.

Environ Pollut

February 2025

School of Studies in Environmental Radiation and Archaeological Sciences, Jadavpur University, Kolkata-700032, West Bengal, India; Department of Physics, Jadavpur University, Kolkata-700032, West Bengal, India. Electronic address:

Use of fertilizers in agriculture soils is a worldwide practice to increase the yield of agricultural products. Fertilizers may contain radioactive elements may be present along with plant's nutrients in fertilizers. Migrated radioactive elements from the fertilized soils can find their entry into the environment and human body through several ways, which may lead to induce a potential radiological risk to human health.

View Article and Find Full Text PDF

The NanoPlasmonic Laser Induced Fusion Energy (NAPLIFE) project proposed fusion by regulating the laser light absorption via resonant nanorod antennas implanted into hydrogen rich urethane acrylate methacrylate (UDMA) and triethylene glycol dimethylacrylate (TEGDMA) copolymer targets. In part of the tests, boron-nitride (BN) was added to the polymer. Our experiments with resonant nanoantennas accelerated protons up to 225 keV energy.

View Article and Find Full Text PDF

A spectroscopy method of alpha particles with the track geometry parameters in CR-39 plastic nuclear track detectors is proposed. The relationship between the track registration sensitivity and incident angle of each etch pit is analyzed. The components of alpha particles emitted from radon, thoron and 241Am can be roughly separated when the etching level is not exceeded beyond the range in CR-39.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!