Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Objective: To evaluate changes in visual acuity and corneal tomographic outcomes at 6 months after femtosecond-laser assisted implantation of two different types of intracorneal implants in keratoconus.
Methods: A total of 39 keratoconus eyes implanted with two segments KeraRing ( = 22 eyes) or MyoRing ( = 17 eyes) were enrolled. Tomographic data (Pentacam system, Oculus) were analyzed and correlated with enhancement in uncorrected (UDVA) and corrected distance visual acuity (CDVA). The tomographic indices were front maximum keratometry (Kmax), corneal asphericity (Q-value) on both surfaces, average pachymetric progression indices (PPI), maximum Ambrosio relational thickness (ARTmax), Belin-Ambrósio enhanced ectasia total deviation index (BAD-D), index of surface variance (ISV), vertical asymmetry (IVA), height asymmetry (IHA) and height decentration (IHD).
Results: LogMAR UDVA and CDVA improved 2.1 ( = 0.003) and 0.7 ( = 0.074) lines with KeraRing, and 8 and 2.5 lines with MyoRing ( = 0.001). The highest and lowest mean differences in the tomographic indices between both groups were related to ISV and IHD, respectively. Changes in all indices differed significantly between two groups except for changes in front corneal astigmatism, ARTmax, ISV, IVA, IHD and IHA ( > 0.05). Correlation of changes in CDVA with changes in other parameters was statistically significant only for IHD in the KeraRing group, while changes in in UDVA were significantly correlated with changes in spherical equivalent, back Q-value, ISV, IVA, and IHA only in the MyoRing group.
Conclusion: Both implants promote corneal shape regularization and an enhancement in UDVA in keratoconus. A considerable flattening effect and reduction in prolateness in the front corneal surface were observed with MyoRing.