Nanoparticle size and 3D shape measurement by electron tomography: An Inter-Laboratory Comparison.

Micron

Nanotechnology Research Centre, National Research Council of Canada, 11421 Saskatchewan Drive, Edmonton, AB, T6G2M9, Canada; Department of Physics, University of Alberta, Edmonton, T6G 2E1, Canada.

Published: January 2021

Electron tomography (ET) has been used for quantitative measurement of shape and size of objects in three dimensions (3D) for many years. However, systematic investigation of repeatability and reproducibility of ET has not been evaluated in detail. To assess the reproducibility and repeatability of a protocol for measuring size and three-dimensional (3D) shape parameters for nanoparticles (NPs) by ET, an inter-laboratory comparison (ILC) has been performed. The ILC included six laboratories and six instruments models from three instrument manufacturers following a standard measurement protocol. A technical specification describing the normative steps of the protocol is published by the International Standards Organization (ISO). Gold NPs with 30 nm nominal diameter contained within a rod-shaped carbon support were measured. The use of a rod-shaped sample support eliminated the missing wedge effect in the experimental tilt series of projected images for improved quantification. A total of 443 NPs were initially measured by NRC-NANO and then 115 out of the 443 NPs were measured by five other labs to compare measurands such as the Volume (V), maximum Feret diameter (F), minimum Feret diameter (F), volume-equivalent diameter (D) and aspect ratio (F) of the NPs. The results of the five labs were compared with the results obtained at NRC-NANO. The maximum disagreement in measurements of F and F obtained by the participating labs did not exceed 7 %. The measured D was between 27.5 nm and 30.3 nm in agreement with the NP manufacturer's specification (28 nm-32 nm). In addition to the above, the influence of the missing wedge effect and beam-induced NP movement was quantified based on the differences of the results between labs.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.micron.2020.102956DOI Listing

Publication Analysis

Top Keywords

electron tomography
8
inter-laboratory comparison
8
missing wedge
8
443 nps
8
feret diameter
8
nps
5
nanoparticle size
4
size shape
4
shape measurement
4
measurement electron
4

Similar Publications

Background: Carotid endarterectomy (CEA) is widely used to treat carotid artery stenosis (CAS). However, the effects of CEA on unilateral CAS-induced cognitive impairment and the underlying mechanism remain poorly understood.

Methods And Results: Thirteen patients diagnosed with unilateral severe CAS underwent pre- and post-CEA assessments, including fluoro-2-deoxy-d-glucose positron emission tomography/magnetic resonance imaging, cognitive assessments, and routine blood tests before and after CEA.

View Article and Find Full Text PDF

Background Toothbrush manufacturers commonly use bristle materials such as nylon, polybutylene terephthalate, polypropylene, polyethylene terephthalate, boar hair, bamboo, carbon fiber, silicone, polylactic acid, or their modifications such as Curen. Nylon filaments have long been demonstrated to be durable and are widely used, but not much is known regarding the performance of Curen filaments compared to nylon filaments. This in vitro study compared the stiffness, abrasion potential, abrasion resistance, and bristle surface changes of Curen and nylon filaments.

View Article and Find Full Text PDF

Rare Earth Selectivity and Electric Potentials at Mica Interfaces.

ACS Appl Mater Interfaces

January 2025

Physical and Computational Sciences Directorate, Pacific Northwest National Laboratory, Richland, Washington 99352, United States.

Controlling materials' composition and structure to selectively adsorb rare earth elements (REE) is critical for better separations. Understanding how local electric potentials affect REE adsorption and how they can be modified via chemical substitution is of fundamental importance. We present calculated mean inner potentials for muscovite and phlogopite micas in excellent agreement with measured values of +10.

View Article and Find Full Text PDF

Dynamic PRC1-CBX8 stabilizes a porous structure of chromatin condensates.

Nat Struct Mol Biol

January 2025

Department of Biochemistry and Molecular Biology, Biomedicine Discovery Institute, Faculty of Medicine, Nursing and Health Sciences, Monash University, Clayton, Victoria, Australia.

The compaction of chromatin is a prevalent paradigm in gene repression. Chromatin compaction is commonly thought to repress transcription by restricting chromatin accessibility. However, the spatial organization and dynamics of chromatin compacted by gene-repressing factors are unknown.

View Article and Find Full Text PDF

Ribosomes, discovered in 1955 by George Palade, were initially described as small cytoplasmic particles preferentially associated with the endoplasmic reticulum (ER). Over the years, extensive research has focused on both the structure and function of ribosomes. However, a fundamental question - how many ribosomes are present within whole cells - has remained largely unaddressed.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!