In this case report, I describe a new technique for total reconstruction of the aortic valve with autologous pericardium. The parameters of the cusps were calculated using very simple formulas after measurement of the aortic root intercommissural distances. Glutaraldehyde-treated pericardium was trimmed along the marked line, leaving 2 mm of tissue along the fibrous annulus attachment margin for the suture and small wings on both commissural margins to secure the commissural coaptation between right and noncoronary cusps. The annular margin of each pericardial cusp was sutured to the corresponding fibrous annulus with running 4/0 polypropylene suture. The commissures of pericardial patch and the commissural coaptation between right and noncoronary cusps were secured with mattress 4/0 polypropylene sutures. The coaptation of the three cusps was checked with negative pressure on the left ventricular vent before closure of the aortotomy. Intraoperative transesophageal echocardiogram revealed a peak pressure gradient of 10 mmHg and trivial aortic regurgitation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7598984 | PMC |
http://dx.doi.org/10.21470/1678-9741-2020-0197 | DOI Listing |
Int J Cardiol Heart Vasc
February 2025
Faculty of Medicine, Tanta University, Tanta, Egypt.
Background: Aortic stenosis (AS) remains a prevalent and serious global health concern, exacerbated by an aging population worldwide. This valvular disease, when symptomatic and without appropriate intervention, severe AS can drastically reduce life expectancy. In our systematic review and -analysis, we aim to synthesize available evidence to guide clinical decision-making by comparing the performance of TAVR and SAVR, specifically in patients with severe AS and a small aortic annulus.
View Article and Find Full Text PDFJ Magn Reson Imaging
January 2025
Clinical Physiology, Department of Clinical Sciences Lund, Lund University, Skåne University Hospital, Lund, Sweden.
Background: Real-time (RT) phase contrast (PC) flow MRI can potentially be used to measure blood flow in arrhythmic patients. Undersampled RT PC has been combined with online compressed sensing (CS) reconstruction (CS RT) enabling clinical use. However, CS RT flow has not been validated in a clinical setting.
View Article and Find Full Text PDFRadiol Case Rep
March 2025
Department of Diagnostic Radiology, Tohoku University Hospital, Sendai, Miyagi, Japan.
Preoperative identification of the Adamkiewicz artery (AKA) with adequate reconstruction or preservation during surgery is useful for protecting the spinal cord from ischemia during thoracoabdominal aortic repair. However, the identification of the AKA remains challenging in some cases, especially with chronic aortic dissection. In a 45-year-old man with chronic aortic dissection requiring thoracoabdominal aortic repair, conventional contrast-enhanced CT or MR angiography failed to detect AKA due to the large entry tear and an enlarged false lumen.
View Article and Find Full Text PDFInt J Biol Macromol
January 2025
Textile Innovation R&D Department, Korea Institute of Industrial Technology, Ansan 15588, Republic of Korea. Electronic address:
Artificial vascular grafts, as blood vessel substitutes, are a prime challenge in tissue engineering and biomaterial research. An ideal artificial graft must have physiological and mechanical properties similar to those of a natural blood vessel, and hemocompatibility on its surface. We designed and fabricated artificial grafts by applying 3D printing and templated technology, which is endowed with morphologically patient-specific vascular reconstruction.
View Article and Find Full Text PDFEur J Radiol
January 2025
Department of Diagnostic and Interventional Radiology, Medical Center-University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; Division of Cardiovascular Imaging, Department of Radiology and Radiological Science, Medical University of South Carolina, Charleston, USA. Electronic address:
Purpose: To evaluate the feasibility of aortoiliac CT-Angiography (CTA) using dual-source photon-counting detector (PCD)-CT with minimal iodine dose.
Methods: This IRB-approved, single-center prospective study enrolled patients with indications for aortoiliac CTA from December 2022 to March 2023. All scans were performed using a first-generation dual-source PCD-CT.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!