LED-based integrating sphere light sources (LED-ISLSs) in the size of typical microscope slides were developed to calibrate the radiance responsivity of optical imaging microscopes. Each LED-ISLS consists of a miniaturized integrating sphere with a diameter of 4 mm, an LED chip integrated on a printed circuit board, and a thin circular aperture with a diameter of 1 mm as the exit port. The non-uniformity of the radiant exitance of the LED-ISLSs was evaluated to be 0.8%. The normal radiance of the LED-ISLSs in the range of (5∼69) W m sr was measured with a standard uncertainty of 1.3% using two precision apertures and a standard silicon photodetector whose spectral responsivity is traceable to an absolute cryogenic radiometer. The LED-ISLSs were applied to calibrate the radiance responsivity of a home-built optical imaging microscope with a standard uncertainty of 2.6∼2.9%. The LED-ISLSs offer a practical way to calibrate the radiance responsivity of various optical imaging microscopes for results comparison and information exchange.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/OE.403899 | DOI Listing |
Lasers Med Sci
December 2024
Hospital for Skin Diseases, Institute of Dermatology, Chinese Academy of Medical Sciences & Peking Union Medical College, Jiangwangmiao Street 12, Xuanwu District, Nanjing, Jiangsu Province, 210042, China.
Traumatic scars negatively impact the patient's quality of life. Fractional 1064 nm Nd: YAG picosecond laser improves scars. However, the effect varies among individuals.
View Article and Find Full Text PDFPlant Dis
December 2024
Clemson University - EREC, Plant and Environmental Sciences, 64 Research Road, Blackville, South Carolina, United States, 29817;
Glossy abelia (Abelia × grandiflora) is an evergreen ornamental shrub used in landscaping globally. From Jun. 2023 to Feb.
View Article and Find Full Text PDFSleep
December 2024
Centre for Biological Timing, Division of Neuroscience, School of Biological Sciences, Faculty of Biology Medicine and Health, University of Manchester, Manchester M13 9PT, UK.
Study Objectives: Melanopsin-expressing retinal ganglion cells, which provide light information to time sleep and entrain circadian clocks, also influence perceived brightness raising the possibility that psychophysical paradigms could be used to explore the origins and implications of variability in melanopic sensitivity. We aimed to develop accessible psychophysical tests of melanopic vision and relate outcomes with a pupillometric measure of melanopsin function (post-illumination pupil response; PIPR) and prior light exposure.
Methods: Individually calibrated pairs of isoluminant stimuli differing in melanopic radiance from a four primary source were presented sequentially with superimposed random colour offsets in a two alternative forced choice brightness preference paradigm to 41 naïve adult participants with personal light exposure data for the prior 7 days and PIPR measures defined by comparing maintained pupil constriction for luminance matched 'red' vs 'blue' pulses.
For commercially available infrared radiometers with a small volume and a light weight and without an independent cooling system for the optical structure, thermal sensitivity is a key constraint for their application to high-precision limb observations. In this research, the response law of a medium wave (3.7-4.
View Article and Find Full Text PDFJ Cosmet Dermatol
October 2024
Integrative Skin Science and Research, Sacramento, California, USA.
Background: There currently exists no consensus on objective features which are relevant in the assessment of overall lip health.
Aims: This study seeks to identify features and factors that are associated with healthy lips. This survey will ultimately enable clinicians to objectively track lip health for clinical evaluations and clinical research.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!