Optical aberrations can greatly distort the image created by an optical element. Several aberrations can affect the image simultaneously and discerning or visualizing specific aberrations can be difficult. By making use of an optically levitated droplet as a light source, we have visualized the spherical aberration and coma of a lens. The droplet approximates a point source in the ray optic regime but, at the same time, creates a diffraction pattern in the far-field region similar to that used in the Ronchi test. When focused by a lens, this micro double point source creates patterns that resemble comets, barreling, hyperbolic triangles, and, most strikingly, a spider. We show how all these patterns are a consequence of spherical aberration and coma. The Zernike polynomials were used to quantify the value of several individual aberrations by comparing them to patterns resulting from numerical simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OE.402759DOI Listing

Publication Analysis

Top Keywords

spherical aberration
12
optically levitated
8
levitated droplet
8
droplet light
8
light source
8
aberration coma
8
point source
8
visualization spherical
4
aberration optically
4
source
4

Similar Publications

Visual Performance Correlation with Corneal Aberrometric Profile and Pupil Size After Implantation of a Trifocal Hydrophobic IOL.

Clin Ophthalmol

December 2024

Département de Recherche Clinique, Institut Ophtalmologique de l'Ouest (IOO) Jules Verne, Nantes, France.

Purpose: To evaluate clinical outcomes obtained after cataract surgery involving the implantation of a trifocal hydrophobic intraocular lens (IOL) and to determine if pupil size and the corneal aberrometric profile correlate to visual acuity at different distances.

Methods: 49 patients (98 eyes) underwent bilateral cataract surgery with the placement of FineVision HP IOLs for presbyopia and were assessed at 1- and 3- to 6-months post-surgery. Postoperatively, refraction, monocular and binocular uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA) and the binocular defocus curve were measured.

View Article and Find Full Text PDF

Proposing lithium pump mechanism for observing Ag-Li two-phase interface reaction of in-situ Li-O battery by two-step method.

J Colloid Interface Sci

January 2025

Hebei Key Laboratory of Applied Chemistry, College of Environmental and Chemical Engineering, Yanshan University, Qinhuangdao 066004 China; Clean Nano Energy Center, State Key Laboratory of Metastable Materials Science and Technology, Yanshan University, Qinhuangdao 066004 China. Electronic address:

Article Synopsis
  • Silver (Ag) is a key catalyst in lithium-oxygen batteries, but its catalytic mechanism is not fully understood.
  • Researchers used Ag nanowires and advanced electron microscopy to study the reactions between Ag and lithium at their interface, revealing that lithiation creates AgLi and oxidation produces Ag nanoparticles.
  • The findings highlight a cyclic reaction process (Ag-AgLi-Ag) that explains lithium transport during discharge and contribute to improved understanding of complex interfacial reactions in these batteries.
View Article and Find Full Text PDF

Terahertz (THz) lens constitutes a vital component in the THz system. Metasurfaces-based THz metalenses and classical bulky lenses are severely constrained by chromatic/ spherical aberration and the diffraction limit. Consequently, achromatic super-resolution THz lenses are urgently needed.

View Article and Find Full Text PDF

Association between axial elongation and corneal topography in children undergoing orthokeratology with different back optic zone diameters.

Eye Vis (Lond)

January 2025

Contact Lens and Visual Optics Laboratory, Optometry and Vision Science, Centre for Vision and Eye Research, Queensland University of Technology, Brisbane, Australia.

Purpose: To explore the associations between myopia defocus dosage (MDD), aberration coefficients (primary spherical aberration and coma), and axial elongation in children undergoing orthokeratology (ortho-k) with back optic zone diameters (BOZD) of 5 mm and 6 mm over 2 years.

Methods: Data from 80 participants from two ortho-k studies were analyzed: 22 and 58 children wore lenses with 5-mm and 6-mm BOZD, respectively. Four MDD metrics were calculated from corneal topography data over a 5-mm pupil for the 1-month and 24-month visits: the circumferential, flat, steep, and volumetric MDD.

View Article and Find Full Text PDF

Talbot effect based sensor measuring grating period change in subwavelength range.

Sci Rep

December 2024

Physical Research Laboratory, Ahmedabad, Gujarat, 380009, India.

Talbot length, the distance between two consecutive self-image planes along the propagation axis for a periodic diffraction object (grating) illuminated by a plane wave, depends on the period of the object and the wavelength of illumination. This property makes the Talbot effect a straightforward technique for measuring the period of a periodic object (grating) by accurately determining the Talbot length for a given illumination wavelength. However, since the Talbot length scale is proportional to the square of the grating period, traditional Talbot techniques face challenges when dealing with smaller grating periods and minor changes in the grating period.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!