A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

A novel light scattering method with size analysis and correction for on-line measurement of particulate matter concentration. | LitMetric

A novel light scattering method with size analysis and correction for on-line measurement of particulate matter concentration.

J Hazard Mater

State Key Laboratory of Coal Combustion, School of Energy and Power Engineering, Huazhong University of Science and Technology, 1037 Luoyu Road, Wuhan 430074, PR China.

Published: January 2021

Based on the difference in particle size sensitivity between forward and backscattering during the measurement of particulate matter (PM) mass concentration using laser angular scattering, a method was proposed to improve its on-line measurement accuracy using three fixed detectors. Experimental and theoretical calculations indicate that the PM mass concentration sensitivity (PMCS) of the particles at the 22.5° detection angle and the asymmetry factor (I/I) are linearly related to the average particle size, and both decrease as the particle size increases. The average particle size obtained from the asymmetry factor was used to correct the PMCS. Compared with the unmodified light scattering method, when the PM mass concentration varies in the range of 1-8 mg⋅m, the average deviation between the light scattering method with particle size correction and the reference is reduced from 191.11 % ± 9.12 % to 8.90 % ± 3.20 %, and the maximum deviation is reduced from 227.04 % to 21.54 %. The effect of particle size on the measurement is reduced by size analysis and correction, and the accuracy of the light scattering method is much improved. Finally, laboratory measurements of the fly ash from coal-fired and biomass-fired power plants were performed.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jhazmat.2020.123721DOI Listing

Publication Analysis

Top Keywords

particle size
24
scattering method
20
light scattering
16
mass concentration
12
size
8
size analysis
8
analysis correction
8
on-line measurement
8
measurement particulate
8
particulate matter
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!