A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of the use of a vessel-sealing device versus ligatures for occlusion of uterine tissues during ovariohysterectomy or ovariectomy in rabbits (). | LitMetric

Objective: To compare the bursting strength of the uterine horns (UHs) and cervical-vestibule junction (CVJs) of rabbits following sealing with a vessel-sealing device (VSD) or encircling ligatures.

Sample: UHs and CVJs collected from 30 rabbit () cadavers.

Procedures: UHs and CVJs were randomly assigned to sealing with encircling Miller knot ligatures (LIG; n = 10 CVJs and 20 UHs) or a VSD (12 CVJs and 24 UHs). Lumens were infused with saline (0.9% NaCl) solution under pressure until seals burst or to a maximum pressure of 300 mm Hg.

Results: For CVJs, median (range) bursting pressure of the LIG and VSD groups was > 300 mm Hg (224 to > 300 mm Hg) and 35 mm Hg (0 to 60 mm Hg), respectively. Five of 12 CVJs in the VSD group failed at pressures < 33 mm Hg. For UHs, median (range) bursting pressure of the LIG and VSD groups was 255 mm Hg (120 to > 300 mm Hg) and 154 mm Hg (range, 44 to 202 mm Hg), respectively.

Conclusions And Clinical Relevance: The evaluated VSD was effective in sealing UHs at bursting pressures well in excess of expected physiologic pressures, indicating that the VSD may be useful for ovariectomy procedures in rabbits. However, CVJ seals created with the VSD were ineffective and could potentially burst at low pressures, which could predispose to urine entering the abdomen. Given these results, we do not recommend sealing of the CVJ with a VSD for ovariohysterectomy in rabbits.

Download full-text PDF

Source
http://dx.doi.org/10.2460/ajvr.81.9.755DOI Listing

Publication Analysis

Top Keywords

vsd
9
vessel-sealing device
8
uhs cvjs
8
cvjs uhs
8
median range
8
range bursting
8
bursting pressure
8
pressure lig
8
lig vsd
8
vsd groups
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!