A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Robotic-assisted surgery in medial unicompartmental knee arthroplasty: does it improve the precision of the surgery and its clinical outcomes? Systematic review. | LitMetric

There is a high prevalence of knee osteoarthritis that affects only the medial tibiofemoral compartment. In this group of patients with severe disease, the medial unicompartmental knee arthroplasty (UKA) is an excellent choice. However, this technique has a great learning curve due to the lower tolerance of improper positioning and alignment. In this context, the robotic-assisted surgery (RAS) arises as an option to improve the accuracy and secondarily enhance the clinical outcomes related to the UKA. The objective in this study is to determine if there are significant advantages with the use of RAS over conventional surgery (CS). In the systematic review of the literature, classification of the results in three main subjects: (A) precision and alignment; (B) functional results and clinical parameters; (C) survivorship. We found 272 studies, of which 15 meet the inclusion and exclusion criteria. There is mostly described that RAS significantly improves the accuracy in position (80-100% of planned versus performed P < 0.05), alignment (2-3 times less error variance P < 0.05) and selection of the proper size of the implants (69.23% of correct size femoral implants versus 16.67% using CS P < 0.0154). Recently, there is mild evidence about benefits in the early rehabilitation and post-operative pain, but in all studies reviewed, there is no advantages of RAS in the long-term functional evaluation. There is no strong literature that supports a longer survival of the prothesis with RAS, being the longest mean follow-up reported of 29.6 months. RAS is a useful tool in increasing the precision of the medial UKA implant placement. However, there is still a lack of evidence that properly correlates this improvement in accuracy with better clinical, functional and survival results.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11701-020-01162-8DOI Listing

Publication Analysis

Top Keywords

robotic-assisted surgery
8
medial unicompartmental
8
unicompartmental knee
8
knee arthroplasty
8
systematic review
8
surgery medial
4
arthroplasty improve
4
improve precision
4
precision surgery
4
surgery clinical
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!