Aim: To compare the in-vitro videokeratoscopic surface dewetting properties of new-generation silicone hydrogel (SiH) planned replacement contact lenses (CL) with those of daily disposable CLs.
Method: A chrome coated cornea model was used for the in-vitro evaluation of surface dewetting. Pre-lens and post-lens film layers were formed by instilling a normal preservative-free normal saline solution (PFNs) (0.9 %) before and after the placement of the CL on the model cornea. The tests were carried out on fanfilcon A, lotrafilcon B, samfilcon A, and senofilcon A lenses, as well as such daily disposable lenses as delefilcon, nesofilcon A and senofilcon one day. Using videokeratoscopic methods, images were obtained at 30-second intervals up to 180 s in the lens and control groups and were analyzed by the ImajeJ® program.
Results: The mean measured area of the keratoscopic rings was largest in the fanfilcon group (67.56 mm), followed by 61.53 mm in the lotrafilcon A group and 64.60 mm in the samfilcon group, while the smallest area was measured in the senofilcon A group, at 56.90 mm. The area was measured as 64.33, 63.09 and 68.39 mm for the delefilcon, nesofilcon and Senofilcon one day CLs, respectively. The dewetting patterns and properties differed in the CL groups (p < 0.05), while no significant differences were found between the measured areas of the planned replacement and daily disposable CL groups (p > 0.05).
Discussion: Videokeratoscopy using in-vitro cornea models has been identified as a reproducible and reliable method for the analysis of the surface dewetting of CLs. The dewetting characteristics of CL groups have been found to differ from each other, despite all being produced from SiH materials. The surface wetting coating has been shown to affect CL dewetting performance.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.clae.2020.10.007 | DOI Listing |
Ophthalmic Physiol Opt
January 2025
School of Optometry and Vision Science, University of New South Wales, Sydney, New South Wales, Australia.
Purpose: To assess the repeatability of lipid layer thickness (LLT) measurement using the LipiView® interferometer after daily disposable contact lens (CL) wear and correlation with ocular comfort in soft contact lens wearers.
Methods: A prospective study was conducted over two consecutive months, wherein CL wearers (n = 20) wore either Somofilcon A or Verofilcon A daily disposable CLs in a crossover design, switching lenses after 1 month. The pre-corneal tear film LLT was measured at the end of each month after CLs had been worn for at least 6 h.
Lancet Respir Med
January 2025
Division of Respiratory Medicine and Gastroenterology, University of Dundee, Ninewells Hospital and Medical School, Dundee, UK. Electronic address:
Background: Bronchiectasis is a disease with a global impact, but most published data come from high-income countries. We aimed to describe the clinical characteristics of patients with bronchiectasis in China.
Methods: The Chinese Bronchiectasis Registry (BE-China) is a prospective, observational cohort enrolling patients from 111 hospitals in China.
Clin Exp Optom
January 2025
Eurolens Research, Division of Pharmacy and Optometry, The University of Manchester, Manchester, UK.
Clinical Relevance: Knowledge of contact lens prescribing trends can (a) assist practitioners to benchmark their own prescribing habits, (b) help the contact lens industry understand preferred products, and (c) support academics in scholarly writings.
Background: This work aims to document contact lens prescribing trends in Australia over the past quarter of a century.
Methods: An annual survey of contact lens prescribing trends was conducted in Australia each year from 2000 to 2024, inclusive, by asking optometrists to provide information relating to 10 consecutive contact lens fits undertaken between January and March.
Int J Biol Macromol
January 2025
College of Biological Engineering, Sichuan University of Science and Engineering, Yibin, Sichuan 644005, China. Electronic address:
Cellulose-based paper is inherently poor in hydrophobicity and mechanical strength, limiting its practical applications in daily life such as packaging materials, water-resistant labels, and disposable tableware. This study aimed to develop an effective and eco-friendly strategy to address these limitations by enhancing the hydrophobicity and mechanical properties of cellulose paper. To achieve this, an internal sizing agent was prepared by combining (3-glycidoxypropyl) trimethoxy (GPS) with natural rosin.
View Article and Find Full Text PDFBull World Health Organ
January 2025
Department of Pharmacy Administration and Clinical Pharmacy, School of Pharmaceutical Sciences, Peking University, 38 Xueyuan Road, Haidian District, Beijing, 100191, China.
Objective: To investigate access to essential anticancer medicines for children throughout China.
Methods: We obtained cross-sectional drug use data for 2021 from 55 tertiary children's hospitals in seven geographical regions (one third of public children's hospitals in mainland China). Affordability was assessed by comparing the single-day copayment for each medicine with the same generic name and route of administration (i.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!