Abnormal mitral flow, what is the cause?

Asian Cardiovasc Thorac Ann

King Abdullah Medical Complex, Jeddah, Ministry of Health, Jeddah, Saudi Arabia.

Published: June 2021

Diastolic mitral regurgitation is a unique Doppler finding that can be missed if special attention is not paid to it. There are a few causes of such abnormal flow, ranging from a conduction abnormality to abnormal valvular and left ventricle function. Failure to recognize it might lead to unnecessary investigations and delay the primary diagnosis. We are presenting a teaching case and discuss the associated pathology.

Download full-text PDF

Source
http://dx.doi.org/10.1177/0218492320970759DOI Listing

Publication Analysis

Top Keywords

abnormal mitral
4
mitral flow
4
flow cause?
4
cause? diastolic
4
diastolic mitral
4
mitral regurgitation
4
regurgitation unique
4
unique doppler
4
doppler finding
4
finding missed
4

Similar Publications

Background: Abnormalities of left ventricular (LV) diastolic function are established independent predictors of heart failure (HF) and mortality.

Objectives: To determine whether the association of diastolic function with all-cause mortality is driven by cardiovascular or non-cardiovascular death and if impaired relaxation mitral inflow filling pattern is a risk marker.

Methods: Diastolic function was graded by the Mayo Clinic algorithm utilizing the well characterized prospective Olmsted County Heart Function Study.

View Article and Find Full Text PDF

Background: Unlike non-rheumatic atrial fibrillation (AF), where left atrial thrombus (LAT) is predominantly confined to the left atrial appendage (LAA), a significant proportion of LAT in rheumatic AF occurs within the left atrial cavity (LAC). However, LAC thrombosis in rheumatic AF has not been extensively studied. This study aimed to evaluate the prevalence of LAT and its subtypes and identify potential predictors of LAT.

View Article and Find Full Text PDF

Plasma Cardiac Troponin-I Concentration in Normal Horses and in Horses with Cardiac Abnormalities.

Animals (Basel)

January 2025

Department of Veterinary Clinical Medicine, College of Veterinary Medicine, University of Illinois, 1008 West Hazelwood Drive, Urbana, IL 61802, USA.

Cardiac troponin-I (cTnI) is a highly sensitive and specific marker of myocardial injury detectable in plasma by immunoassay techniques. Inclusion criteria over a 3-year period required a diagnosis of cardiac disease accompanied by electrocardiographic (ECG) and cardiac ultrasound examinations (n = 23) in adult horses (≥2 years of age). A second group of normal adult ponies (n = 12) was studied as a reference group.

View Article and Find Full Text PDF

We describe a rare but interesting complication of totally endoscopic robotic mitral valve repair in a patient with severe mitral regurgitation. The mitral valve was repaired robotically by standard techniques, and the intraoperative transesophageal echocardiogram demonstrated no residual mitral regurgitation. However, there was unexpected hypokinesia of the posterior and lateral walls of the left ventricle, with subsequent electrocardiography showing acute ST elevations of the lateral segment.

View Article and Find Full Text PDF

Background: Ebstein's anomaly represents 40% of congenital tricuspid valve abnormalities. Studies about paediatric Ebstein's anomaly patients are limited.

Aim: To evaluate clinical characteristics, treatment (medical/arrhythmia ablation/surgical) results, and outcome of Ebstein's anomaly patients, and to determine factors affecting arrhythmia presence and mortality.

View Article and Find Full Text PDF