The main purpose in the diagnosis of human immunodeficiency virus (HIV) infection is to rapidly and accurately identify people with HIV infection. It is recommended that samples that are repeatedly reactive should be verified/supported according to the classical algorithms of international and national guidelines. The recombinant "line immunoassay test (LIA)", which has been used for many years, is studied with the accumulated samples to be cost and labor-effective. In this study, the supplemental recombinant HIV 1/2 LIA (INNO-LIA®, Fujirebio, Ghent, Belgium) used to confirm and differentiate the diagnosis of HIV-1 and HIV-2 infections, and an immunochromatographic supplemental test (Geenius™ (Bio-Rad Laboratories, Marnes-la-Coquette, France) which can provide faster results were compared. One hundred fifty serum samples sent to Ege University Faculty of Medicine Hospital Medical Virology Laboratory with anti-HIV 1/2 and p24 antigen positive and indeterminant results and three HIV-1 positive external quality control samples were included in the study. Samples were tested both with the Geenius™ HIV 1/2 (Bio-Rad Laboratories, Marnes-la-Coquette, France) and recombinant HIV 1/2 LIA (INNO-LIA®, Fujirebio, Ghent, Belgium). HIV 1 viral load was evaluated by using Abbott real-time HIV-1 test in Abbott m200sp system (Abbott Molecular, Wiesbaden, Germany) in plasma samples. In both assays, the results were consistent in 147 samples (96.08%). Six samples that have discordant results were as follows: one sample was LIA HIV-1 positive and Geenius indeterminate, two samples were LIA indeterminant and Geenius HIV-1 positive, and in three samples, LIA was indeterminate and Geenius negative. In two EIA reactive samples (2/97, 2.06%) and three EIA negative samples (3/53, 5.66%) LIA results were indeterminant. Geenius test, on the other hand, correctly identified HIV positive and negative samples. The immunochromatographic test could be used in the diagnostic algorithm of HIV infection, due to its short application time, not being labor intensive, its ability to distinguish HIV-1/2, its high sensitivity/specificity compared to LIA, and the compliance with LIA. However, it should be noted that in acute HIV infection, all analytical antibody tests, become reactive later than the fourth generation enzyme immunoassays.

Download full-text PDF

Source
http://dx.doi.org/10.5578/mb.69786DOI Listing

Publication Analysis

Top Keywords

hiv 1/2
20
hiv infection
16
samples
13
recombinant hiv
12
hiv-1 positive
12
hiv
11
lia
8
1/2 lia
8
lia inno-lia®
8
inno-lia® fujirebio
8

Similar Publications

Background: International migrants are central to HIV research, but comparative data on their infection rates versus resident populations, including in Chile, are scarce. This study compares HIV incidence rates between international migrants and Chileans.

Methods: A longitudinal study was conducted.

View Article and Find Full Text PDF

Feasibility of implementing viral hepatitis services into a correctional service facility in Cape Town, South Africa.

Int J Drug Policy

January 2025

Division of Hepatology, Department of Medicine, Faculty of Health Sciences, University of Cape Town and Groote Schuur Hospital, Main Road, Observatory, Cape Town, South Africa. Electronic address:

Background: Hepatitis B virus (HBV) and hepatitis C virus (HCV) are estimated to be of the most prevalent infectious diseases in correctional settings worldwide. However, viral hepatitis services have not been routinely integrated into South African correctional facilities. We aimed to assess prevalence of HBV infection and HCV infection among people accessing HIV services and assess the feasibility of viral hepatitis service integration in a South African correctional centre.

View Article and Find Full Text PDF

Introduction: The mortality rate among Human immunodeficiency Virus (HIV) who have started antiretroviral therapy (ART) continues to be increased in resource-limited countries, despite a decline in developed nations. Furthermore, research within this age group is limited and has not previously been conducted in the study area. Consequently, this study aimed to determine the incidence of mortality and its predictors among HIV-positive children who have been receiving ART at public health facilities in West Wollega.

View Article and Find Full Text PDF

Introduction: Dolutegravir is now extensively used in sub-Saharan Africa as a preferred component of antiretroviral therapy (ART). There is a paucity of large studies using routinely collected data from African people living with HIV on dolutegravir-based regimens to inform HIV programmes. We reviewed data in a large programme clinic of people living with HIV on dolutegravir to determine the real-world safety and tolerability of dolutegravir and to describe drivers of treatment discontinuation.

View Article and Find Full Text PDF

Background: There is increasing recognition that the interpretation of active-controlled HIV prevention trials should consider the counterfactual placebo HIV incidence rate, that is, the rate that would have been observed if the trial had included a placebo control arm. The PrEPVacc HIV vaccine and pre-exposure prophylaxis trial (NCT04066881) incorporated a pre-trial registration cohort partly for this purpose. In this article, we describe our attempts to model the counterfactual placebo HIV incidence rate from the registration cohort.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!