Nowadays, 3D printing technologies are among the rapidly developing technologies applied to manufacture even the most geometrically complex models, however no techniques dominate in the area of craniofacial applications. This study included 12 different anatomical structures of the mandible, which were obtained during the process of reconstructing data from the Siemens Somatom Sensation Open 40 system. The manufacturing process used for the 12 structures involved the use of 8 3D printers and 12 different polymer materials. Verification of the accuracy and radiological density was performed with the CT160Xi Benchtop tomography system. The most accurate results were obtained in the case of models manufactured using the following materials: E-Model (Standard Deviation (SD) = 0.145 mm), FullCure 830 (SD = 0.188 mm), VeroClear (SD = 0.128 mm), Digital ABS-Ivory (SD = 0.117 mm), and E-Partial (SD = 0.129 mm). In the case of radiological density, ABS-M30 was similar to spongious bone, PC-10 was similar to the liver, and Polylactic acid (PLA) and Polyethylene terephthalate (PET) were similar to the spleen. Acrylic resin materials were able to imitate the pancreas, kidney, brain, and heart. The presented results constitute valuable guidelines that may improve currently used radiological phantoms and may provide support to surgeons in the process of performing more precise treatments within the mandible area.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7690625PMC
http://dx.doi.org/10.3390/polym12112444DOI Listing

Publication Analysis

Top Keywords

radiological density
12
anatomical structures
8
printing technologies
8
assessing radiological
4
density accuracy
4
accuracy mandible
4
mandible polymer
4
polymer anatomical
4
structures manufactured
4
manufactured printing
4

Similar Publications

Predictive model of intrahepatic collateral vessels among hepatic veins in patients with liver tumors involving the caval confluence.

Surgery

January 2025

Department of Biomedical Sciences, Humanitas University, Milan, Italy; Department of Hepatobiliary & General Surgery, IRCCS Humanitas Research Hospital, Milan, Italy. Electronic address:

Background: Communicating vessels among hepatic veins in patients with tumors invading/compressing hepatic veins at their caval confluence facilitate new surgical solutions. Although their recognition by intraoperative ultrasound has been described, the possibility of preoperative detection still remains uncertain. We aimed to develop a model to predict their presence before surgery.

View Article and Find Full Text PDF

Background: MRI offers quantification of proton density fat fraction (PDFF) and tissue characteristics with T1 mapping. The influence of age, sex, and the potential confounding effects of fat on T1 values in skeletal muscle in healthy adults are insufficiently known.

Purpose: To determine the accuracy and repeatability of a saturation-recovery chemical-shift encoded multiparametric approach (SR-CSE) for quantification of T1 and muscle fat content, and establish normative values (age, sex) from a healthy cohort.

View Article and Find Full Text PDF

Breast MRI to Screen Women With Extremely Dense Breasts.

J Magn Reson Imaging

January 2025

Department of Radiology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.

Women with extremely dense breasts are at a higher risk of breast cancer, and the sensitivity of mammography in this group is reduced due to the masking effect of overlapping tissue. This review examines supplemental screening methods to improve detection in this population, with a focus on MRI. Morphologic techniques offer limited benefits, digital breast tomosynthesis (DBT) shows inconsistent results, and ultrasound (US), while improving cancer detection rates (CDR), results in a higher rate of false positives.

View Article and Find Full Text PDF

The e-STROKE study is a prospective, multicenter observational study designed to assess the impact of various CT parameters (including e-ASPECT, CT perfusion (CTP), collateral flow status, and the size and location of the ischemic lesion) on the clinical outcomes of patients with ischemic stroke, as evaluated by the modified Rankins Scale (mRS) three months post-stroke. This study also aims to investigate whether the use of multimodal CT imaging increases the number of patients eligible for recanalization therapy. The analysis will integrate data from the RES-Q registry and radiological data from the e-STROKE system provided by Brainomix Ltd.

View Article and Find Full Text PDF

Significance: Decoding naturalistic content from brain activity has important neuroscience and clinical implications. Information about visual scenes and intelligible speech has been decoded from cortical activity using functional magnetic resonance imaging (fMRI) and electrocorticography, but widespread applications are limited by the logistics of these technologies.

Aim: High-density diffuse optical tomography (HD-DOT) offers image quality approaching that of fMRI but with the silent, open scanning environment afforded by optical methods, thus opening the door to more naturalistic research and applications.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!