A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Conduction disorders after aortic valve replacement with rapid-deployment bioprostheses: early occurrence and one-year evolution. | LitMetric

Background: Rapid-deployment bioprostheses represent one of the newest aortic valve substitutes introduced into clinical practice. The aim of this retrospective single-center study was to evaluate the occurrence of conduction disorders (CDs) after rapid-deployment aortic valve implantation at discharge and at 1-year follow-up, and to identify risk factors for CDs and permanent pacemaker implantation (PPI).

Methods: All patients who reached 1-year follow-up after isolated or combined aortic valve replacement (AVR) with rapid-deployment bioprostheses (Intuity Elite, Edwards Lifesciences, Irvine, CA) at our institution were included in this study. Standard 12-lead electrocardiograms (ECGs) were recorded before the procedure (within 24 hours), after the procedure as soon as the patient was moved to the intensive care unit (ICU), every day during in-hospital stay and at 1-year follow-up. The primary endpoint was the incidence of postoperative CDs at discharge and at 1-year follow up. Patients were divided in two groups: those who developed the primary endpoint (Group CD) and those who didn't (Group Non-CD).

Results: A total of 98 consecutive patients were included in the study. At discharge, the primary endpoint occurred in 40 patients (40.8%). In particular, new CDs and PPI occurred in 33 (33.7%) and in 7 (7.1%) patients, respectively. Valve size was the only independent predictor of primary endpoint at discharge. At 1-year, 30 patients (31.3%) presented with CDs or pacemaker-induced rhythm. In particular, in 25 patients of Group CD (64.1%), 1-year follow-up ECG revealed the persistence of the same CD as at discharge or pacemaker-induced rhythm, while 14 patients (35.9%) showed recovery of their CD. Age and prosthesis size were identified as independent predictors of CDs/pacemaker-induced rhythm at 1-year follow-up.

Conclusions: According to our data, nearly 40% of patients develop a new CD after rapid-deployment aortic valve implantation. Of these, one third recover after one year. Bioprosthesis size and age were identified as independent risk factors for occurrence of CD after surgery.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7548210PMC
http://dx.doi.org/10.21037/acs-2020-surd-14DOI Listing

Publication Analysis

Top Keywords

aortic valve
20
1-year follow-up
16
primary endpoint
16
rapid-deployment bioprostheses
12
discharge 1-year
12
patients
9
conduction disorders
8
valve replacement
8
rapid-deployment aortic
8
valve implantation
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!