At this time, green analytical chemistry is gaining more interest and concern. The present work details three green spectrofluorimetric methods for tramadol (TRM) determination using ibuprofen (IBU) (mixture 1) and chlorzoxazone (CLZ) (mixture 2). In first method, two excitation wavelengths (λ ), 220 and 280 nm, were used to record the emission spectra for IBU and TRM, respectively (mixture 1) followed by a first derivative treatment. For mixture 2, one λ (280 nm) was optimum for both drugs followed by a first derivative technique for TRM and a second derivative for CLZ determinations. The second method measured the first derivative values for synchronous spectra using constant-wavelength mode at 280 nm for TRM and 260 nm for IBU, and at 270 nm for TRM and 292 nm for CLZ. The third method used constant-energy mode to record synchronous spectra. First derivative values were computed at 282 nm for TRM and 260 nm for IBU in mixture 1 and at 272 nm for TRM and 292 nm for CLZ in mixture 2. ICH validation guidelines were assessed in full and assay of the two TRM binary mixtures in their drug products was successful. Green profile evaluation for the developed methods compared with the reported chromatographic methods was performed using the 'analytical eco-scale' and the 'green analytical procedure index'. These two assessment tools corroborated that the proposed methods achieved the most green parameters, therefore recommending their use as a green option for analyzing the studied drugs in bulk and dosage forms for routine quality control.

Download full-text PDF

Source
http://dx.doi.org/10.1002/bio.3969DOI Listing

Publication Analysis

Top Keywords

green spectrofluorimetric
8
spectrofluorimetric methods
8
methods tramadol
8
trm
8
ibu mixture
8
clz mixture
8
derivative values
8
synchronous spectra
8
trm 260
8
260 ibu
8

Similar Publications

The current study introduces the first micellar-enhanced spectrofluorimetric approach for the estimation of the commonly abused CNS antitussive, dextromethorphan (DXM) in its syrup and biological fluids. A micellar solution of sodium dodecyl sulfate (SDS) containing DXM showed high native fluorescence emission at 305 nm following excitation at 224 nm. Using SDS as a micellar system resulted in about a 2.

View Article and Find Full Text PDF

Pizotifen maleate (PZM) is an anti-migraine drug. Effective treatment requires accurate measurement of PZM levels in patients and constant medication concentrations in tablets. This paper presents a new spectrofluorimetric approach for detecting PZM in tablets and human blood plasma (spiked with PZM).

View Article and Find Full Text PDF

Hypertension is the predominant risk factor for cardiovascular diseases and mortality. This study presents the first method for the simultaneous analysis of the co-administered antihypertensive drugs, Carvedilol (CAR) and Telmisartan (TEL) using a fast, highly sensitive, environmentally friendly, and cost-effective second derivative synchronous spectrofluorimetric approach. The fluorescence of CAR and TEL was quantified at 243 nm and 274.

View Article and Find Full Text PDF
Article Synopsis
  • * A new microwave-assisted spectrofluorimetric technique was developed using environmentally friendly solvents and a fluorescent probe to reduce organic waste, meeting industry validation standards.
  • * The proposed method was found to be user-friendly, cost-effective, and environmentally sustainable, effectively minimizing ecological impact while providing reliable drug analysis.
View Article and Find Full Text PDF

Nateglinide is an oral meglitinide that treats diabetes. Nateglinide was determined in several commercial formulations using chromatographic and spectrophotometric methods in published research. Quality-by-design approach was applied to develop the in-house nateglinide-loaded Solid Dispersion Adsorbate (SDA) for improving bioavailability and solubility.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!