Epidermal electrophysiology is widely carried out for disease diagnosis, performance monitoring, human-machine interaction, etc. Compared with thick, stiff, and irritating gel electrodes, emerging tattoo-like epidermal electrodes offer much better wearability and versatility. However, state-of-the-art tattoo-like electrodes are limited in size (e.g., centimeters) to perform electrophysiology at scale due to challenges including large-area fabrication, skin lamination, and electrical interference from long interconnects. Therefore, we report large-area, soft, breathable, substrate- and encapsulation-free electrodes designed into transformable filamentary serpentines that can be rapidly fabricated by cut-and-paste method. We propose a Cartan curve-inspired transfer process to minimize strain in the electrodes when laminated on nondevelopable skin surfaces. Unwanted signals picked up by the unencapsulated interconnects can be eliminated through a previously unexplored electrical compensation strategy. These tattoo-like electrodes can comfortably cover the whole chest, forearm, or neck for applications such as multichannel electrocardiography, sign language recognition, prosthetic control or mapping of neck activities.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7608837PMC
http://dx.doi.org/10.1126/sciadv.abd0996DOI Listing

Publication Analysis

Top Keywords

tattoo-like electrodes
12
epidermal electrophysiology
8
electrophysiology scale
8
electrodes
7
electrically compensated
4
tattoo-like
4
compensated tattoo-like
4
electrodes epidermal
4
scale epidermal
4
electrophysiology carried
4

Similar Publications

Surface electromyography (sEMG) is a commonly used technique for the non-invasive measurement of muscle activity. However, the traditional electrodes used for sEMG often have limitations regarding their long-term wearability. This study explored the feasibility of a wearable platform using a tattoo-like epidermal electrode (e-tattoo) for multi-day sEMG monitoring.

View Article and Find Full Text PDF

Pd-conformally coated, one-end-embedded gold nanowire percolation network for intrinsically stretchable, epidermal tattoo fuel cell.

Biosens Bioelectron

February 2023

Department of Chemical & Biological Engineering, Faculty of Engineering, Monash University, Clayton, 3800, Victoria, Australia; Melbourne Center for Nanofabrication, Clayton, 3168, Victoria, Australia. Electronic address:

Soft, conformal and wearable epidermal fuel cells may offer promising energy solutions to power next-generation on-skin electronics on-demand anytime anywhere. However, it is non-trivial to design intrinsically stretchable electrode in order to maintain the fuel cell performance under real-world and dynamic mechanical deformations. Here, we present a tattoo-like epidermal fuel cell based on Pd conformally-coated, one-end-embedded percolation gold nanowire (EP-AuNW/EP-AuPdNW) networks, which are in essence the combination of in-plane percolation conductivity and out-plane anisotropic conductivity.

View Article and Find Full Text PDF

Electrically compensated, tattoo-like electrodes for epidermal electrophysiology at scale.

Sci Adv

October 2020

State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology, Wuhan 430074, China.

Epidermal electrophysiology is widely carried out for disease diagnosis, performance monitoring, human-machine interaction, etc. Compared with thick, stiff, and irritating gel electrodes, emerging tattoo-like epidermal electrodes offer much better wearability and versatility. However, state-of-the-art tattoo-like electrodes are limited in size (e.

View Article and Find Full Text PDF

Soft Bioelectronic Stickers: Selection and Evaluation of Skin-Interfacing Electrodes.

Adv Healthc Mater

August 2019

Soft and Printed Microelectronics Lab, Institute of Systems and Robotics, University of Coimbra, Coimbra, 3030-290, Portugal.

Surface biopotentials collected from the human epidermis contain important information about human physiology, such as muscular, heart, and brain activities. However, commercially available wearable biomonitoring devices are generally composed of rigid hardware incompatible with the mechanical compliance of soft human tissues. Thin-film stretchable e-skin circuits that can interface the human skin represent an excellent alternative for long-term wearable biomonitoring.

View Article and Find Full Text PDF

This paper introduces stretchable, long-term wearable, tattoo-like dry surface electrodes for highly repeatable electromyography (EMG). The tattoo-like sensors are hair thin, skin compliant and can be laminated on human skin just like a temporary transfer tattoo, which enables multi-day noninvasive but intimate contact with the skin even under severe skin deformation. The new electrodes were used to facilitate a system-based approach to tracking of long-term fatiguing and recovery processes in a human neuromusculoskeletal (NMS) system, which was based on establishing an autoregressive moving average model with exogenous inputs (ARMAX model) relating signatures extracted from the surface electromyogram (sEMG) signals collected using the tattoo-like sensors, and the corresponding hand grip force (HGF) serving as the model output.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!