Treatment of locally advanced adenocarcinoma of the gastroesophageal junction (GEJ) with chemoradiation may be associated with high rates of symptomatic cardiac toxicity. Large margins are typically required to ensure coverage of GEJ tumors with free-breathing volumetric modulated arc therapy (VMAT) radiotherapy. The purpose of this study is to determine whether treatment with tighter margins enabled by maximum-inhalation breath hold (MIBH)-gated intensity modulated radiation therapy (IMRT) on an integrated MRI-linear accelerator system (MR-linac) can decrease radiation doses to the heart and cardiac substructures. Ten patients with locally advanced GEJ adenocarcinoma underwent both free breathing 4-dimensional computed tomography (4DCT) and MIBH MRI simulation scans. MR-linac IMRT plans were created with a 3 mm clinical target volume (CTV) to planning target volume (PTV) isotropic margin and 4DCT VMAT plans were created with a 11, 13, and 9 mm CTV to PTV anisotropic margins in the left-right, cranial-caudal, and anterior-posterior directions according to GEJ-specific PTV expansion recommendations by Voncken et al. Prescription dose to PTV was 50.4 Gy in 28 fractions. Dosimetry to the heart and cardiac substructures was compared with paired t test; p < 0.05 was considered significant. Mean PTV on the MR-linac IMRT plans was significantly smaller compared to the 4DCT VMAT plans (689 cmvs 1275 cm, p < 0.01). Mean dose to the heart and all cardiac substructures was significantly lower in the MR-linac IMRT plans compared to the 4DCT VMAT plans: heart 20.9 Gy vs 27.8 Gy, left atrium 29.6 Gy vs 39.4 Gy, right atrium 20.5 Gy vs 25.6 Gy, left ventricle 21.6 Gy vs 29.6 Gy, and right ventricle 18.7 Gy vs 25.2 Gy (all p values <0.05). MIBH-gated MR-linac IMRT treatment of locally advanced GEJ adenocarcinoma can significantly decrease doses to the heart and cardiac substructures and this may translate to reduced rates of cardiac toxicity.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.meddos.2020.10.002DOI Listing

Publication Analysis

Top Keywords

heart cardiac
12
cardiac substructures
12
mr-linac imrt
12
imrt plans
12
4dct vmat
12
vmat plans
12
locally advanced
8
plans created
8
target volume
8
compared 4dct
8

Similar Publications

The widespread application of genome editing to treat and cure disease requires the delivery of genome editors into the nucleus of target cells. Enveloped delivery vehicles (EDVs) are engineered virally derived particles capable of packaging and delivering CRISPR-Cas9 ribonucleoproteins (RNPs). However, the presence of lentiviral genome encapsulation and replication proteins in EDVs has obscured the underlying delivery mechanism and precluded particle optimization.

View Article and Find Full Text PDF

Evaluation of endothelialization of an occluder device with cardiac computed tomography and assessment of the pathological validation.

PLoS One

January 2025

Department of Structural Heart Disease, Cardiovascular Institute and Fuwai Hospital, National Center for Cardiovascular Diseases, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.

Background: Assessing the endothelialization of occlusive devices noninvasively remains a challenge. Cardiac computed tomography angiography (CTA) can be employed to evaluate device endothelialization based on contrast uptake within the occluder.

Objective: This study examined device endothelialization using cardiac CTA and investigated the pathological associations.

View Article and Find Full Text PDF

Preterm births constitute a major public health issue and a chronic, cross-generational condition globally. Psychological and biological factors interact in a way that women from low socio-economic status (SES) are disproportionally affected by preterm delivery and at increased risk for the development of perinatal mental health problems. Low SES constitutes one of the most evident contributors to poor neurodevelopment of preterm infants.

View Article and Find Full Text PDF

Background: Motor imagery is the mental representation of a movement without physical execution. When motor imagery is performed to enhance motor learning and performance, participants must reach a temporal congruence between the imagined and actual movement execution. Identifying factors that can influence this capacity could enhance the effectiveness of motor imagery programs.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!