We report a case of cardiogenic shock due to severe aortic stenosis in a 55-year-old patient with a congenital unicuspid aortic valve (UAV). An emergent aortic valvuloplasty was performed in the spoke catheterization laboratory which allowed to achieve transient stabilization of the hemodynamic parameters and to move the patient to the nearest hub hospital with on-site cardiac surgery. Since the surgical risk of an aortic valve replacement was deemed too high, a transcatheter procedure was performed with implantation of a self-expandable prosthesis. The final result was suboptimal due to a moderate residual paravalvular leak, but the patient experienced rapid recovery and was discharged 10 days after the procedure. Just a few cases of transcatheter aortic valve replacement due to severe aortic stenosis in UAV have been described but, to the best of our knowledge, this is the first one in a clinical setting of cardiogenic shock. Although the gold standard treatment for UAV is surgical intervention, this case demonstrates that the transcatheter procedure is feasible and may play a role as a bridge to definitive surgical replacement.

Download full-text PDF

Source
http://dx.doi.org/10.1714/3413.33965DOI Listing

Publication Analysis

Top Keywords

aortic valve
16
cardiogenic shock
12
severe aortic
12
aortic valvuloplasty
8
aortic
8
unicuspid aortic
8
shock severe
8
aortic stenosis
8
valve replacement
8
transcatheter procedure
8

Similar Publications

Background: Conduction disturbances are common after transcatheter aortic valve implantation (TAVI) and frequently require permanent pacemaker implantation (PPI). Data regarding its impact on mortality and morbidity are conflicting. This study aims to assess the impact of PPI before or within 30 days after TAVI on mortality and health-related Quality of Life (QoL) during the first year after TAVI.

View Article and Find Full Text PDF

A 70-year-old man developed intermittent fever with chills, severe anorexia, generalized weakness, and mild exertional difficulty in breathing following posterior chamber intraocular lens replacement surgery for a mature white cataract in the left eye. Laboratory tests revealed persistent negative blood cultures, normocytic and normochromic anemia, neutrophilia, and elevated inflammatory markers despite multiple courses of antibiotics. All other investigations conducted to identify the cause of prolonged fever, including transthoracic echocardiography, were negative.

View Article and Find Full Text PDF

Background: The initial outcomes of transcatheter aortic valve replacement in patients with left ventricular outflow tract calcification are poor. Furthermore, balloon-expandable transcatheter aortic valve replacement is associated with an increased risk of annular rupture, and self-expandable transcatheter aortic valve replacement is associated with worse post-operative residual paravalvular leakage grades. Therefore, developing an optimal method for transcatheter aortic valve replacement for patients with left ventricular outflow tract calcification is desirable.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!