It is critical to understand the relationship between under-body blast (UBB) loading and occupant response to provide optimal protection to the warfighter from serious injuries, many of which affect the spine. Previous studies have examined component and whole body response to accelerative based UBB loading. While these studies both informed injury prediction efforts and examined the shortcomings of traditional anthropomorphic test devices in the evaluation of human injury, few studies provide response data against which future models could be compared and evaluated. The current study examines four different loading conditions on a seated occupant that demonstrate the effects of changes in the floor, seat, personal protective equipment (PPE), and reclined posture on whole body post-mortem human surrogate (PMHS) spinal response in a sub-injurious loading range. Twelve PMHS were tested across floor velocities and time-to-peak (TTP) that ranged from 4.0 to 8.0 m/s and 2 to 5 ms, respectively. To focus on sub-injurious response, seat velocities were kept at 4.0 m/s and TTP ranged from 5 to 35 ms. Results demonstrated that spine response is sensitive to changes in TTP and the presence of PPE. However, spine response is largely insensitive to changes in floor loading. Data from these experiments have also served to develop response corridors that can be used to assess the performance and predictive capability of new test models used as human surrogates in high-rate vertical loading experiments.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10439-020-02656-0DOI Listing

Publication Analysis

Top Keywords

spine response
12
response
9
response sub-injurious
8
vertical loading
8
ubb loading
8
changes floor
8
ttp ranged
8
loading
7
evaluation body
4
spine
4

Similar Publications

Comparison of Recruitment Method on Clinical Outcomes Following Cervical Disc Arthroplasty.

Spine (Phila Pa 1976)

January 2025

Indiana Spine Group Location of investigation Indiana Spine Group, 13225 N. Meridian Street, Carmel, IN 46032.

Study Design: Retrospective cohort.

Objective: To compare the clinical outcomes of trial versus standard clinical practice (SCP) patients following cervical disc arthroplasty (CDA).

Background: CDA is hypothesized to reduce the shear strain and related complications resulting from fusion procedures.

View Article and Find Full Text PDF

Protein-activated kinases mediate spine morphogenesis and synaptic plasticity. PAK3 is part of the p21-activated kinases (PAKs) family of Ras-signaling serine/threonine kinases. Pathogenic variants in the X-linked gene PAK3 have been described in patients with neurodevelopmental syndromes.

View Article and Find Full Text PDF

, a rare human pathogen, has limited clinical data. This case report presents a case of sepsis, pyelonephritis, and septic spondylitis treated successfully with ampicillin. An 82-year-old woman was hospitalized for acute pyelonephritis and sepsis, presenting with fever and abdominal pain.

View Article and Find Full Text PDF

Knowledge, interest and perspectives on Artificial Intelligence in Neurosurgery. A global survey.

Brain Spine

December 2024

Section of Neurosurgery, Department of Neurosciences, Biomedicine and Movement Sciences, University of Verona, Verona, Italy.

Article Synopsis
  • AI applications in healthcare, especially neurosurgery, are rapidly increasing, highlighting the need for understanding AI fundamentals to inform decisions on its future use.
  • A global survey of 250 neurosurgeons revealed limited knowledge of AI concepts, with only a few respondents accurately defining key terms like Machine Learning and Deep Learning.
  • Despite low familiarity with AI basics, a strong interest and positive attitude towards integrating AI into neurosurgery were noted, with barriers such as lack of funding and infrastructure identified as key challenges.
View Article and Find Full Text PDF

A Novel Dynamic Growth Rod Inducing Spinal Growth Modulation for the Correction of Spinal Deformities.

JOR Spine

March 2025

Beijing Key Laboratory for Design and Evaluation Technology of Advanced Implantable & Interventional Medical Devices, Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering Beihang University Beijing China.

Background: Growth rods are the gold standard for treating early-onset scoliosis (EOS). However, current treatments with growth rods do not optimize spinal growth in EOS patients, and frequent distraction surgeries significantly increase complications, imposing considerable economic and psychological burdens on patients. An improved growth rod is urgently required to address the need for dynamic growth and external regulation.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!