AI Article Synopsis

  • This research compared low modulus carbon fiber-reinforced polyetheretherketone (CF-PEEK) composite plates to traditional stainless steel and titanium alloy plates for fixing tibial shaft fractures using finite element analysis.
  • Results showed that the CF30 plate had the highest maximum displacement and exhibited failure under 700 N of force, while the CF50 plate provided a balanced performance with the lowest stress shielding rate, benefiting fracture healing.
  • The findings suggest that CF50 plates are a safe option for tibial fractures, demonstrating potential biomechanical advantages over metal plates and warranting further investigation into CF-PEEK materials.

Article Abstract

Purpose: In this research, low modulus carbon fiber (CF)-reinforced polyetheretherketone composite plates (CF-PEEK plates) were compared with traditional metal plates using finite element analysis to establish a reference for clinical application.

Material And Methods: Plates of stainless steel, titanium alloy (Ti6Al4V), or CF-PEEK with different carbon fiber reinforcement ratios (CF30, CF50, and CF60) were used to fix the tibial shaft comminuted fracture. The maximum stress, the maximum displacement of fracture and the stress shielding of cortex bone were analyzed.

Results: Under 200 N axial compression, the maximum displacement was measured in the CF30 plate (4.62 mm) and the minimum in the stainless steel plate (0.23 mm). The stress shielding rates of stainless steel, titanium, CF30, CF50, and CF60 plates were 59.4%, 54.4%, 23.75%, 48.75% and 66.25%. Under 700 N axial compression, the internal fixation by the CF30 plate failed. Among the other 4 plates, the maximum displacement was measured in the CF50 plate (2.52 mm) and the minimum in the stainless steel plate (0.78 mm). The stress shielding rate of plates made of stainless steel, titanium, CF50, and CF60 were 57.1%, 52.0%, 48.1%, and 67.8%.

Conclusions: CF50 plates can be safely used in the tibial shaft comminuted fracture. The micromotion in the CF50 and CF60 plate was more beneficial to callus formation and fracture healing. The stress shielding of the cortex bone under the CF50 plate was the lowest. The finite element analysis indicated that the CF-PEEK material is worthy of further study because of its biomechanical advantages.

Download full-text PDF

Source
http://dx.doi.org/10.1080/08941939.2020.1836290DOI Listing

Publication Analysis

Top Keywords

stainless steel
20
cf50 cf60
16
stress shielding
16
tibial shaft
12
shaft comminuted
12
finite element
12
element analysis
12
steel titanium
12
maximum displacement
12
carbon fiber
8

Similar Publications

Cold atmospheric plasma (CAP) has emerged as a promising technology for neutralizing microbes, including multidrug-resistant strains. This study investigates CAP's potential as an alternative to traditional antimicrobial drugs for microbial inactivation. In the era of increasing antimicrobial resistance, there is a persistent need for alternative antimicrobial strategies.

View Article and Find Full Text PDF

Harmless and efficient nickel enrichment from nickel-containing waste slag using vitrification technology.

Environ Sci Pollut Res Int

January 2025

Qingdao Qingli Environmental Protectionquipmen Co, LTD, Jiaozhou, 266300, China.

With the growing demand for nickel in the stainless steel and battery industries, conventional methods of extracting nickel from ores face challenges such as high production costs and environmental concerns. This study proposes a new process for the recovery of nickel metal and the production of nickel-iron alloys from nickel-bearing scrap. The reduction rates of nickel and iron oxides were investigated by optimizing the roasting temperature, time, and C/O ratio, and the process was optimized using response surface methodology (RSM).

View Article and Find Full Text PDF

Manufacturing of Liposomes Using a Stainless-Steel Microfluidic Device: An Investigation into Design of Experiments.

Langmuir

January 2025

Department of Polymer and Materials Chemistry, Faculty of Chemistry & Petroleum Sciences, Shahid Beheshti University, P.O. Box 1983969411 Tehran, Iran.

Liposomes are highly beneficial nanocarrier systems due to their biocompatibility, low toxicity, and exceptional inclusiveness, which lead to improved drug bioavailability. For biological applications, accurate control over these nanoparticles' mean size and size distribution is essential. Micromixers facilitate the continuous production of liposomes, enhancing the precision of size regulation and reproducibility.

View Article and Find Full Text PDF

One area of technological advancement has been the shift from stainless steel hand tools to nickel-titanium (Ni-Ti) rotary tools. This paper aims to perform an in vitro comparative study to evaluate the efficacy of five endodontic manual and rotary instruments such as Kerr files, Orodeka Plex V, ProTaper Flydent NiTi super files, and ProTaper Flydent NiTi super files in combination with an ultrasonic endodontic E3D Diamantata EMS scaler used for root canal shaping. The following aspects were highlighted: effective removal of smear layer (SL) from the dentinal tubules in the coronal 1/3, middle 1/3, and apical 1/3 of the root canal, appearance of cracks in the dentinal walls by SEM analysis, and highlighting of dentin mineral content and remnant debris by EDX analysis.

View Article and Find Full Text PDF

The aging population necessitates a critical need for medical devices, where polymers-based surface lubrication coating is essential for optimal functionality. In fact, lubrication and mechanical requirements vary depending on the service environment of different medical devices. Until now, key mean is still blank for general preparation of hydrophilic polymers-based lubrication coatings with on-demand mechanics and lubricity.

View Article and Find Full Text PDF