Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Background: Proximal humeral fracture-dislocations (PHFD) are a special entity in proximal humeral fracture treatment. The aim of this study is to present our minimally invasive plate osteosynthesis (MIPO) technique through an anterolateral deltoid split approach. In addition, we performed a retrospective cohort study analyzing the patient reported functional outcome and complications.
Methods: A single center cohort study was performed. All patients operated through a deltoid split approach for PHFD between 2009 and 2016 were eligible for inclusion. The primary endpoint was subjective shoulder function measured with QuickDASH and subjective shoulder value (SSV). Secondary endpoints were complications and implant-related irritation.
Results: 28 patients were included. The mean age was 49 (SD ± 10.3). The mean follow-up was 48 months (SD ± 23.7). The mean QuickDASH score was 6.8 (SD ±7.8) and the mean SSV was 86 (SD ±14.6). Four patients had a conversion into a reversed arthroplasty (14%), one patient (4%) a shortening of secondary perforated screws, four patients an early re-osteosynthesis (14%), four patients (14%) developed an AVN and in one patient damage of the axillary nerve was observed. 21 patients (75%) had their implant removed.
Conclusion: Patient reported functional results after humeral head preservation and internal fixation of PHFDs through an anterolateral deltoid spilt approach are promising. However, there is a high rate of re-operations either because of complications or for implant removal. Comparing our data to literature these rates are not depending on the approach chosen.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7547160 | PMC |
http://dx.doi.org/10.22038/abjs.2020.42728.2162 | DOI Listing |