Spectral quality is an important factor for in vitro development of explants in a bioreactor system. Based on the need to optimize micropropagation for  ×  clones, the aim of the study was to assess the spectral quality of in vitro multiplication in temporary immersion bioreactor (TIB). The tissue used to generate the explants (i.e., the nodal segment with 1 cm of length and two axillary bud without leaves) was previously in vitro established and multiplied it derived from ministumps of  ×  clone grown in a semi-hydroponic system. The spectral quality of in vitro multiplication was assessed through five light sources (i.e., fluorescent lamp, red, green, blue, and yellow cellophane). Morphological and anatomical features of tissues grown in TIB were evaluated at 90 days. Based on the results, yellow and blue spectral qualities were the most suitable to be adopted for in vitro multiplication of  × , since they enabled lesser hyperhydricity, favors high number of shoots per explant and shoot length, as well as thicker mesophyll and spongy parenchyma; arise as an alternative for large-scale production of eucalypts clonal plants.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7525561PMC
http://dx.doi.org/10.1007/s13205-020-02447-3DOI Listing

Publication Analysis

Top Keywords

spectral quality
16
vitro multiplication
16
temporary immersion
8
immersion bioreactor
8
multiplication  × 
8
quality vitro
8
vitro
6
spectral
5
quality temporary
4
bioreactor vitro
4

Similar Publications

Multi-Energy Evaluation of Image Quality in Spectral CT Pulmonary Angiography Using Different Strength Deep Learning Spectral Reconstructions.

Acad Radiol

December 2024

Radiomics and Augmented Intelligence Laboratory (RAIL), Department of Radiology and the Norman Fixel Institute for Neurological Diseases, University of Florida College of Medicine, Gainesville, FL (M.H-S., H.S.S., A.G.R., S.E.M., J.C.P., E.Y.A., B.H., R.F.); Department of Radiology, University of Florida College of Medicine, Gainesville, FL (M.H-S., H.S.S., A.G.R., J.C.P., E.Y.A., B.H., R.F.); Division of Medical Physics, University of Florida College of Medicine, Gainesville, FL (R.F.); Department of Neurology, Division of Movement Disorders, University of Florida College of Medicine, Gainesville, FL (R.F.); Department of Otolaryngology - Head and Neck Surgery, McGill University, Montreal, Quebec, Canada (R.F.); Department of Radiology, AdventHealth Medical Group, Maitland, FL (R.F.). Electronic address:

Rationale And Objectives: To evaluate and compare image quality of different energy levels of virtual monochromatic images (VMIs) using standard versus strong deep learning spectral reconstruction (DLSR) on dual-energy CT pulmonary angiogram (DECT-PA).

Materials And Methods: A retrospective study was performed on 70 patients who underwent DECT-PA (15 PE present; 55 PE absent) scans. VMIs were reconstructed at different energy levels ranging from 35 to 200 keV using standard and strong levels with deep learning spectral reconstruction.

View Article and Find Full Text PDF

Gamma-ray coded-aperture imaging technology has important applications in the fields of nuclear security, isolated source detection, and the decommissioning of nuclear facilities. However, artifacts can reduce the quality of reconstructed images and affect the identification of the intensity and location of radioactive sources. In this paper, a gamma-ray coded-aperture imaging method based on primitive and reversed coded functions (PRCF) was proposed to reduce imaging artifacts.

View Article and Find Full Text PDF

Objectives: Phosphorus-31 magnetic resonance spectroscopic imaging (P-MRSI) is a non-invasive tool for assessing cellular high-energy metabolism in-vivo. However, its acquisition suffers from a low sensitivity, which necessitates large voxel sizes or multiple averages to achieve an acceptable signal-to-noise ratio (SNR), resulting in long scan times.

Materials And Methods: To overcome these limitations, we propose an acquisition and reconstruction scheme for FID-MRSI sequences.

View Article and Find Full Text PDF

The introduction of benchtop NMR instruments has made NMR spectroscopy a more accessible, affordable option for research and industry, but the lower spectral resolution and SNR of a signal acquired on low magnetic field spectrometers may complicate the quantitative analysis of spectra. In this work, we compare the performance of multiple neural network architectures in the task of converting simulated 100 MHz NMR spectra to 400 MHz with the goal of improving the quality of the low-field spectra for analyte quantification. Multi-layered perceptron networks are also used to directly quantify metabolites in simulated 100 and 400 MHz spectra for comparison.

View Article and Find Full Text PDF

[PLSR model based on near-infrared spectroscopy for the detection of wood fiber anatomy of ].

Ying Yong Sheng Tai Xue Bao

October 2024

Research Institute of Subtropical Forestry, Chinese Academy of Forestry/Zhejiang Key Laboratory of Forest Genetics and Bree-ding, Hangzhou 311400, China.

To rapidly acquire fiber phenotypic data for wood quality assessment, we used a portable NIR spectro-meter to collect spectral data in 100 individuals of at 18-year-old of 20 different provenances, and simultaneously collected wood cores. Wood basic density and the anatomical structure of wood fiber were measured. The standard normal variate (SNV), orthogonal signal correction (OSC), and multiplicative scatter correction (MSC) methods were used for spectral preprocessing, the competitive adaptive reweighted sampling (CARS) method were used for wavelength selection, and the partial least squares regression (PLSR) model were established.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!