Automated computation of relative flow resistance using a pulsed Doppler flowmeter.

J Appl Physiol (1985)

Department of Physiology and Biophysics, Louisiana State University Medical Center, School of Medicine in Shreveport 71130.

Published: September 1987

Use of a pulsed Doppler flowmeter to assess changes in blood flow resistance often requires a laborious series of calculations, and full characterization of resistance changes frequently necessitates replotting of calculated data. To facilitate the interpretation of pulsed Doppler flowmetry data, a simple, inexpensive device was constructed that computes the signal ratio of mean arterial pressure (MAP) to directional pulsed Doppler outputs. With this device, relative flow resistance can be recorded and quantitatively assessed at a glance in three vascular beds in real time. This computer-like device was designed around the Burr-Brown DIV100HP integrated circuit. C741G OpAmps provide input buffering, zeroing, and ranging adjustments enabling the user to accurately follow resistance over a very broad range of changes without exceeding the device's operating limits. A LM339 quad comparator monitors the input of each DIV100 and indicates when operating limits are exceeded via a channel-specific LED indicator and an audible alarm. No significant attenuation of the input signals occurs over the range of direct current to 50 kHz, and the output is without significant phase shift. Comparisons with calculated changes in resistance derived from the MAP and pulsed Doppler flowmetry in unanesthetized, unrestrained rats confirmed that resistance changes can be measured with precision and accuracy.

Download full-text PDF

Source
http://dx.doi.org/10.1152/jappl.1987.63.3.1284DOI Listing

Publication Analysis

Top Keywords

pulsed doppler
20
flow resistance
12
relative flow
8
doppler flowmeter
8
resistance changes
8
doppler flowmetry
8
operating limits
8
resistance
7
pulsed
5
doppler
5

Similar Publications

Introduction: The severity of mitral stenosis (MS) is commonly assessed using mitral valve area (MVA) measured with transthoracic echocardiography (TTE). The dimensionless index (DI) of mitral valve (MV) was recently studied in degenerative MS. We evaluated DI MV in rheumatic MS and studied its relationship with clinical outcomes.

View Article and Find Full Text PDF

Background: Superior caval vein obstruction is a rare complication of endocardial pacing lead implantation that can result in a right to left shunt.

Case Summary: A 3-year-old child with type 2 Brugada syndrome presented with mild cyanosis post-endocardial pacing implantation due to evolutionary right superior caval vein obstruction. This obstruction resulted in a right to left shunt across a previously unrecognized patent levo-atrial cardinal vein associated with partial anomalous pulmonary venous drainage.

View Article and Find Full Text PDF

To what extent sildenafil, a selective inhibitor of the type-5 phosphodiesterase modulates systemic redox status and cerebrovascular function during acute exposure to hypoxia remains unknown. To address this, 12 healthy males (aged 24 ± 3 y) participated in a randomized, placebo-controlled crossover study involving exposure to both normoxia and acute (60 min) hypoxia (Fi = 0.14), followed by oral administration of 50 mg sildenafil and placebo (double-blinded).

View Article and Find Full Text PDF

Objectives: Multiple techniques have been proposed for functional fetal cardiology, including pulsed-wave (PW) and tissue Doppler imaging (TDI), Myocardial Performance Index (MPI), annular plane systolic excursion (TAPSE/MAPSE) and spatiotemporal image correlation (STIC). We aimed to compare these techniques' achievability and reproducibility to determine their clinical utility for each cardiac side.

Methods: Uncomplicated pregnancies from 22 to 39 weeks were recruited and images and volumes stored for offline analysis.

View Article and Find Full Text PDF

Even if rarely detected, right atrial (RA) masses represent a diagnostic challenge due to their heterogeneous presentation. Para-physiological RA structures, such as a prominent Eustachian valve, Chiari's network, and lipomatous atrial hypertrophy, may easily be misinterpreted as pathological RA masses, including thrombi, myxomas, and vegetations. Each pathological mass should always be correlated with adequate clinical, anamnestic, and laboratory data.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!