We present a retrospective of unique micro-fabrication problems and solutions that were encountered through over 10 years of retinal prosthesis product development, first for the Boston Retinal Implant Project initiated at the Massachusetts Institute of Technology and at Harvard Medical School's teaching hospital, the Massachusetts Eye and Ear-and later at the startup company Bionic Eye Technologies, by some of the same personnel. These efforts culminated in the fabrication and assembly of 256+ channel visual prosthesis devices having flexible multi-electrode arrays that were successfully implanted sub-retinally in mini-pig animal models as part of our pre-clinical testing program. We report on the processing of the flexible multi-layered, planar and penetrating high-density electrode arrays, surgical tools for sub-retinal implantation, and other parts such as coil supports that facilitated the implantation of the peri-ocular device components. We begin with an overview of the implantable portion of our visual prosthesis system design, and describe in detail the micro-fabrication methods for creating the parts of our system that were assembled outside of our hermetically-sealed electronics package. We also note the unique surgical challenges that sub-retinal implantation of our micro-fabricated components presented, and how some of those issues were addressed through design, materials selection, and fabrication approaches.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7603138PMC
http://dx.doi.org/10.3390/mi11100944DOI Listing

Publication Analysis

Top Keywords

visual prosthesis
12
sub-retinal implantation
8
micro-fabrication components
4
components high-density
4
high-density sub-retinal
4
sub-retinal visual
4
prosthesis
4
prosthesis retrospective
4
retrospective unique
4
unique micro-fabrication
4

Similar Publications

Local field potential phase modulates the evoked response to electrical stimulation in visual cortex.

J Neural Eng

January 2025

Department of Physiology and Department of Electrical and Computer System Engineering, Monash University - Clayton Campus, Wellington Rd, Melbourne, Victoria, 3800, AUSTRALIA.

Development of cortical visual prostheses requires optimization of evoked responses to electrical stimulation to reduce charge requirements and improve safety, efficiency, and efficacy. One promising approach is timing stimulation to the local field potential (LFP), where action potentials have been found to occur preferentially at specific phases. To assess the relationship between electrical stimulation and the phase of the LFP, we recorded action potentials from primary (V1) and secondary (V2) visual cortex in marmosets while delivering single-pulse electrical microstimulation at different phases of the local field potential.

View Article and Find Full Text PDF

Purpose: To evaluate the 12-month rotational stability and outcomes of V4c toric Implantable Collamer Lenses (TICLs) (STAAR Surgical) located at two different lens orientations (horizontal or oblique).

Methods: This retrospective study included a total of 403 eyes with TICL implantation, enrolled between January 2021 and December 2022, that were divided into two groups based on the minimum intended angle off the horizontal axis: horizontal with 263 eyes at an angle ±22.5 degrees or less and oblique with 140 eyes at a minimum intended angle of greater than ±22.

View Article and Find Full Text PDF

Purpose: To observe and explore the correlation between visual outcomes and intraocular lens (IOL) stability after tri-focal IOL implantation in eyes with high myopia.

Methods: Patients with highly myopic cataract (axial length > 26 mm) were enrolled in this prospective study. Thirty-one eyes (31 patients) received implantation of a trifocal IOL (AcrySof IQ PanOptix TFNT00).

View Article and Find Full Text PDF

Evaluating interface pressure in a lower-limb prosthetic socket: Comparison of FEM and experimental measurements on a roll-over simulator.

J Biomech

January 2025

Arts et Métiers Institute of Technology, Université Sorbonne Paris Nord, IBHGC - Institut de Biomécanique Humaine Georges Charpak, HESAM Université, 151 boulevard de l'Hôpital, 75013 Paris, France. Electronic address:

Improper socket fitting in lower-limb prostheses can lead to significant complications, including pain, skin lesions, and pressure ulcers. Current suspension and socket design practices rely predominantly on visual inspection of the residual limb and patient feedback. Monitoring stress distribution at the residual limb/socket interface offers a more objective approach.

View Article and Find Full Text PDF

Intraoperatively identified patellofemoral osteoarthritis: no significant impact on short-term outcomes of medial unicompartmental knee arthroplasty.

BMC Musculoskelet Disord

January 2025

Department of Orthopaedic Surgery, The First Affiliated Hospital, Fujian Medical University, No.20, Chazhong road, Fuzhou, 350005, China.

Background And Objective: The efficacy of medial unicompartmental knee arthroplasty (UKA) in patients with intraoperatively identified patellofemoral osteoarthritis (PFOA) has been a subject of debate. This retrospective study aimed to investigate the early outcomes of UKA in patients with varying intraoperative PFOA conditions and to explore the relationship between the location of PFOA and the position of the prosthesis post-UKA. Our aim was to determine whether the presence of PFOA affects the short-term success of medial UKA.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!