Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Metal artefacts in PET/CT images hamper diagnostic accuracy in head and neck cancer (HNC). The aim of this study is to characterise the clinical effects of metal artefacts on PET/CT in HNC and to inform decision-making concerning implementation of MAR techniques. We study a combined dual energy CT and inpainting-based metal artefact reduction (DECT-I-MAR) technique for PET/CT in three settings: (A) A dental phantom with a removable amalgam-filled tooth to evaluate the PET error in comparison to a known reference. (B) PET-positive patients with metallic implants to demonstrate the relationship between CT metal artefacts and PET error. (C) Metabolic tumour volumes delineated in PET-positive patients with metal implants to evaluate the clinical impact. In (A) DECT-I-MAR reduced the PET error significantly. In (B) we demonstrate an increasing PET error with increasing CT artefact severity in patients. In (C) it is shown that the presence of artefacts in the same axial slices as the tumour significantly decreases biomarker stability and increase delineation variability. This work shows the practical feasibility of DECT-I-MAR-based PET/CT imaging, and indicates a positive clinical impact of using the technique routinely for HNC patients. The impact of CT artefacts on PET is considerable, especially in workflows where quantitative PET biomarkers and tumour volumes are used. In such cases, and for patients with tumours in proximity of metals, we recommend that a MAR technique for PET/CT is employed.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1088/1361-6560/abc366 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!