The high capacity of neural networks allows fitting models to data with high precision, but makes generalization to unseen data a challenge. If a domain shift exists, i.e. differences in image statistics between training and test data, care needs to be taken to ensure reliable deployment in real-world scenarios. In digital pathology, domain shift can be manifested in differences between whole-slide images, introduced by for example differences in acquisition pipeline - between medical centers or over time. In order to harness the great potential presented by deep learning in histopathology, and ensure consistent model behavior, we need a deeper understanding of domain shift and its consequences, such that a model's predictions on new data can be trusted. This work focuses on the internal representation learned by trained convolutional neural networks, and shows how this can be used to formulate a novel measure - the representation shift - for quantifying the magnitude of model-specific domain shift. We perform a study on domain shift in tumor classification of hematoxylin and eosin stained images, by considering different datasets, models, and techniques for preparing data in order to reduce the domain shift. The results show how the proposed measure has a high correlation with drop in performance when testing a model across a large number of different types of domain shifts, and how it improves on existing techniques for measuring data shift and uncertainty. The proposed measure can reveal how sensitive a model is to domain variations, and can be used to detect new data that a model will have problems generalizing to. We see techniques for measuring, understanding and overcoming the domain shift as a crucial step towards reliable use of deep learning in the future clinical pathology applications.

Download full-text PDF

Source
http://dx.doi.org/10.1109/JBHI.2020.3032060DOI Listing

Publication Analysis

Top Keywords

domain shift
32
deep learning
12
shift
10
domain
9
learning histopathology
8
neural networks
8
proposed measure
8
techniques measuring
8
data
7
measuring domain
4

Similar Publications

Objectives: This research describes four aspects of the development of the Sense of Safety Theoretical Framework for whole person care: exploring the meaning of the phrase "sense of safety"-the whole person ; the range of human experience that impacts sense of safety-whole person ; the dynamics that build sense of safety-the healing ; and the personal and cross-disciplinary trauma-informed practitioner that facilitate sense of safety.

Methods: This qualitative participatory study was conducted in two phases. Researchers iteratively explored the concept of sense of safety using focus groups and semi-structured interviews.

View Article and Find Full Text PDF

Terahertz reconfigurable intelligent surfaces (RIS) stand out from conventional phased arrays thanks to their unique electromagnetic properties and intelligent interconnect paradigms. They are a vital technology for terahertz wireless communication and radar detection systems. Compared with 1-bit coding metasurfaces, 2-bit coding metasurfaces offer significant advantages such as single beam steering and reduced quantization errors.

View Article and Find Full Text PDF

We report a hybrid Brillouin optical frequency/correlation-domain analysis technique, capable of accurate and high spatial resolution Brillouin frequency shift (BFS) profile measurements in optical fibers. The method relies on a conventional Brillouin optical frequency domain analysis (BOFDA) configuration, with an additional sinusoidal frequency modulation (FM) applied to the pump and probe beams. Such frequency modulation synthetizes a sequence of narrow correlation peaks along the fiber, which are simultaneously interrogated through BOFDA.

View Article and Find Full Text PDF

Ghost holography has attracted notable applied interest in the modern quantitative imaging applications with the futuristic features of complex field recovery in the diversified imaging scenarios. However, the utilization of digital holography in ghost frame works introduces space bandwidth or time bandwidth restrictions in the implementation of the technique in applied domains. Here, we propose and demonstrate a quantitative ghost phase imaging approach with holographic ghost diffraction scheme in combination with the phase-shifting technique.

View Article and Find Full Text PDF

In this study, we developed terahertz (THz) metamaterial devices with attenuated total reflection (ATR) geometries for biosensing applications. This was achieved by transferring the metamaterial patterns fabricated on a polyimide film to a prism-top surface. We characterized the resonance characteristics of metasurfaces for different THz wave polarizations and gap structure orientations in the metamaterials.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!