Current and emerging concepts in biological and analytical variation applied in clinical practice.

J Vet Intern Med

Syn Laboratories - Veterinary Pathology Group (VPG), Torrance-Diamond Diagnostic Laboratories, University of Exeter, The Innovation Centre, Exeter, UK.

Published: November 2020

A single laboratory result actually represents a range of possible values, and a given laboratory result is impacted not just by the presence or absence of disease, but also by biological variation of the measurand in question and analytical variation of the equipment used to make the measurement. Biological variation refers to variability in measurand concentration or activity around a homeostatic set point. Knowledge of biological and analytical variation can be used to facilitate interpretation of patient clinicopathologic data and is particularly useful for interpreting serial patient data and data at or near reference limits or clinical decision thresholds. Understanding how biological and analytical variation impact laboratory results is of increasing importance, because veterinarians evaluate serial data from individual patients, interpret data from multiple testing sites, and use expert consensus guidelines that include decision thresholds for clinicopathologic data interpretation. The purpose of our report is to review current and emerging concepts in biological and analytical variation and discuss how biological and analytical variation data can be used to facilitate clinicopathologic data interpretation. Inclusion of veterinary clinical pathologists having expertise in laboratory quality management and biological variation on research teams and veterinary practice guideline development teams is recommended, to ensure that various considerations for clinicopathologic data interpretation are addressed.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC7694803PMC
http://dx.doi.org/10.1111/jvim.15929DOI Listing

Publication Analysis

Top Keywords

analytical variation
24
biological analytical
20
clinicopathologic data
16
biological variation
12
data interpretation
12
variation
9
data
9
current emerging
8
emerging concepts
8
biological
8

Similar Publications

Validation of lactate and glucose in cerebrospinal fluid (CSF) on a Radiometer blood gas analyzer ABL90 Flex plus.

Clin Biochem

January 2025

Pathology and Laboratory Medicine Program, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada; Memorial University of Newfoundland, Health Sciences Centre, St. John's, Newfoundland and Labrador, Canada. Electronic address:

Purpose: Rapid determination of cerebrospinal fluid. (CSF) glucose and lactate is required by emergency rooms and intensive care units. Long turnaround time (TAT) on test results negatively impacts timely diagnosis and treatment of neurological infections like meningitis.

View Article and Find Full Text PDF

Background: Syphilis is a sexually transmitted infection (STI) that can be prevented and effectively treated; yet it continues to be a cause of morbidity and mortality worldwide. There is a limited understanding of the epidemiology of syphilis in the Middle East and North Africa (MENA) region.

Methods: A systematic review conducted up to April 30, 2024 assessed the prevalence of syphilis and followed PRISMA guidelines, without language and date restrictions.

View Article and Find Full Text PDF

Automated electrochemical oxygen sensing using a 3D-printed microfluidic lab-on-a-chip system.

Lab Chip

January 2025

Nanobioelectronics Laboratory (NBEL), Department of Biomedical Engineering, Ilse Katz Institute for Nanoscale Science and Technology, Ben-Gurion University of the Negev, 8410501 Beer Sheva, Israel.

Dissolved oxygen is crucial for metabolism, growth, and other complex physiological and pathological processes; however, standard physiological models (such as organ-on-chip systems) often use ambient oxygen levels, which do not reflect the lower levels that are typically found . Additionally, the local generation of reactive oxygen species (ROS; a key factor in physiological systems) is often overlooked in biology-mimicking models. Here, we present a microfluidic system that integrates electrochemical dissolved oxygen sensors with lab-on-a-chip technology to monitor the physiological oxygen concentrations and generate hydrogen peroxide (HO; a specific ROS).

View Article and Find Full Text PDF

Boraginaceae plants, including four endemic species from Türkiye, were analyzed for organic and inorganic compositions using ICP-MS and LC-MS/MS to explore their nutritional, medicinal, and ecological significance. This study examined 18 species, identifying key elements such as sodium (87,600.359-118,049.

View Article and Find Full Text PDF

Iontronic sensors based on confined space have garnered significant attention due to their promising applications, ranging from single-cell analysis to studies. However, their limited sensitivity has constrained their effectiveness in studying molecular information during physiological and pathological processes. Here, we demonstrate an electrolyte-gated ionic transistor (EGIT) by integrating the confined ion transport behavior in a double-barreled micropipet with an electrolyte-gated transistor configuration, achieving highly sensitive and selective sensing.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!